NOTICE
1. Install the detector properly according to manual.
Do not touch the sensor surface in order not to decrease
the sensitivity. If the sensor needs to be cleaned, use soft
cloth with little alcohol after cutting off the power.
2. The detector can decrease the rate of the accident but
can not assure no risk at all. For safety concern, besides
proper usage of the detector, please enhance vigilance
and take good protection in daily life.
3. Constant power supply should be provided to ensure
proper operation . Walking test should be carried out
periodically. Once a week is recommended.
OPERATING INSTRUCTIO
N
Jumper setting
1)
PULSE Jumper:
Adjust sensitivity and the
detection speed.
Short 1&2: Class 1 pulse, high sensitivity, good anti
RF interference ability, suits for ordinary
environment.
Short 2&3: Class 2 pulse, low sensitivity, strong anti
RF interference ability, suits for environments with
heavy RF interference.
2)
Relay Jumper:
Choose N.C. or N.O. to set the
state of alarm output according to different
requirements of alarm host.
Short 1 & 2: N.O.
Short 2 & 3: N.C. (Default)
3)
Delay Jumper:
Used to set the lasting time of
relay and alarm indicator when alarming.
Short 1&2: 3S ( Default)
Short 2&3: 30S
4)
LED Jumper:
Used to control LED indicator. This
function will not influence the normal detector’s
operation. In order to provide better concealment,
the LED indicator can be off after test by pulling out
all the jumpers.
PRODUCT TESTING
Connecting power supply (DC12V), LED indicator flashes,
the detector will go into self testing state for about 60s.
When the LED indicator off, the detector enters into
normal working state. For testing walk within the detection
range in parallel with the wall where the detector is
installed. When the LED indicator lights, the detector
enters into alarm state.
JUMPER SETTING FIGURE
2
Top & Side
views Detection Pattern PIR-730
DETECTING AREA VIEW
0m
6m
2m
4m
8m
3.6m
0m
2m
4m
2m
4m
0m
2m
4m
2m
4m
1
2
3
1
2
3
1
2
3
OPEN
2&3
1&2
1
RELAY JUMPER
2
LED JUMPER
3
DELAY JUMPER
4
PULSE JUMPER
1
2
3
4
LED On
Pulse count
Relay Mode
Delay