6.9.1 Configuration steps using SYNCLT (Area sensor)
Configuration steps for using Area sensor are as follows.
Figure6-20: Software configuration steps : Simple flow(Area sensor)
6.9.2 Configuration steps using SYNCLT (Line sensor)
Configuration steps for using Line sensor are as follows.
Figure6-21: Software configuration steps : Simple flow (Line sensor)
1. Open and Initialization
2. Configuration CC Output
(
with notice
)
4. Start capturing
Open master board and slave board.
Initialize master board and slave board.
Configure slave board to output CC by SYNCLT_IN.
Configure master board to output CC normally.
The slave board that outputs CC by SYNCLT_IN must
start capturing in first.
5. Stop capturing
Stop Capturing.
Order stopping does not have particular restriction
3. Reflect configurations
Reflect configurations to Hardware
1. Open and Initialization
2. Configuration CC Output
(
with notice
)
5. Start capturing
(
with notice
)
Open master board and slave board.
Initialize master board and slave board.
Configure slave board to output CC by SYNCLT_IN.
Configure master board to output CC normally.
The slave board that outputs CC by SYNCLT_IN must
start capturing in first.
6. Stop capturing
Stop Capturing.
Order stopping does not have particular restriction
3. Reflect configurations
Reflect configurations to Hardware
4. Stop Outputting CC
In the case of a line sensor, Output CC is begun
before start capturing. SYNC_LT is also outputted.
Summary of Contents for APX-3302