background image

AW49200HTA, HTS

User’s Manual

PAGE 12

Technical Support

 (650) 384-0000

www.avalanwireless.com

Technical specifications

CHARACTERISTIC

SPECIFICATION/DESCRIPTION

RF transmission rate

216 Mbps

Ethernet data rate

Up to 130 Mbps

Output power AW49200HTA 

Access Point

4 watts EIRP with 9 dBi omnidirectional antenna

Output power AW49200HTS 

Subscriber Unit

4 watts EIRP with 23 dBi directional antenna

Power Consumption

17 Watts maximum

Receiver Sensitivity

-115 dBm for HTS configurations, -101 dBm for the HTA

Frequency Range

4.940 GHz - 4.990 GHz, 5.150 - 5.250 GHz and 5.745 - 5.850 GHz 

Channel Bandwidth

20 MHz

RF channels

11 total - 2x Licensed Channels at 4.9 GHz and 9x Unlicensed for 5 GHz 

bands

Modulation

OFDM (BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM)

Range

Line-of-sight range up to 5 miles for HTA/HTS point-to-point

Browser Management Tools

QoS Statistics, Network Settings, Channel Selection

Data Security

128-bit AES-CCM

Operating Environment

-40ºC to +70ºC, IP66, sealed for outdoor operation: die cast aluminum 

package with rubber gasket seals

Mounting

Heavy Duty Pole-Mount Bracket included

Connector

10/100/1000 Ethernet RJ-45 with weatherproof sealing gland

Power System

Power Over Ethernet 24 VDC Injectors included: 100-240 VAC 50/60Hz 

primary source

AW49200HTA Antennas

Omnidirectional, 9 dBi gain in horizontal plane, 16” long

AW49200HTA Size

8.75” Square by 3.25” case plus 16” tall antenna, weight 7 lbs

AW49200HTS  Antenna

Integrated 23 dBi flat panel, 13” square, 10° Beamwidth

AW49200HTS Size

13” by 13” by 3.25”, not including pole-mount bracket, weight 7 lbs

Warranty

1 Year Parts & Labor, XTRa-Care extended warranty available

Certification

FCC, IC

Summary of Contents for AW49200HTA

Page 1: ...USER S MANUAL Industrial grade long range wireless Ethernet systems AvaLAN W I R E L E S S AW49200HTA AW49200HTS 4 9 GHz Outdoor 200 Mbps Wireless Ethernet Access Point and Subscriber Unit Radios ...

Page 2: ... any antenna other than those provided with the product is forbidden in accordance to FCC rules CFR47 part 15 204 Professional installation is required for radio equipment with N Type antenna connectors to ensure compliance with radio frequency output power For compliance with health safety for radio energy exposure regulations a minimum distance of 63 cm must be maintained between the antennae an...

Page 3: ...ess Point Username admin Password password Best Practices 1 Ensure clear visual path between radios before deployment 2 Test on bench before deployment 3 Networking Cable CAT 6 Shielded Outdoor Grade For AW49200 maximum length 60 ft 20 meters AW49200HTA Access Point AW49200HTS Subscriber Units POE POE Up to 5 miles Line of Sight Supported Networking cable not provided Multipoint to Point POE Netwo...

Page 4: ...ywhentheproductispowered and is lit solid when it has a successful wireless connection The wireless activity light blinks when receiving data The Ethernet activity light blinks when receiving data Thewirelessstatuslightblinksslowlywhentheproductispowered and is lit solid when it has a successful wireless connection This light will blink when receiving data This light will blink when transmitting d...

Page 5: ...enu on the left to navigate from section to section The menu looks like this when its sections are expanded Beware that certain actions may cause the web page to freeze In most cases this is because you are viewing a browser cached version of the page and not the live one from the radio Clear your browser cache and or logout and log back in to recover You are cautioned not to use the back button o...

Page 6: ...nges first because the link will be broken if the network name or Security Keys do not agree 1 Setting the IP Address and Subnet Mask Gateway and Device Name In the upper right area of the Quick Set page are the data entry boxes for these parameters They contain the current values A special notation is used for the IP Address and Subnet Mask Use x at the end of the IP Address to specify the subnet...

Page 7: ...the new password twice in the boxes indicated Click the Change button Log out and log back in to test 3 Setting the Frequency Network name and Encryption Key To set the Frequency log in to the Access Point and on the quick start page a selection can be made The Network name is an arbitrary character string that must be set alike in all linked radios The encryption key is a user specified character...

Page 8: ...in Menu at the left side of the window The Wireless page leads to most of the useful status information The table on the Interfaces tab provides a list of the interface processes running in this radio If it is a Subscriber Unit there will be only one Wireless_Radio If it is an Access Point there will also be a WDS process running for each Subscriber Unit that is connected These very long rows summ...

Page 9: ... enough to rotate Narrow Pole Mounting Place the pole between the large wedge of the Bracket Arm A and the small wedge on the reversed side of the Pole Clamp Bar Use the two Clamp Bolts to bind the bar and bracket to the pole Use Large Washers and Lock Washers if needed Leave the clamp loose enough to rotate Wall Mounting Hold Bracket Arm A flush against the wall then drill four holes of roughly 3...

Page 10: ...be pointed toward their Access Point AW49200HTA Care should be taken to align the AW49200HTS panel antenna to provide the best performance The HTS antenna performs best when the panel s face is aligned toward its partner By browsing to the Access Point radio you can see a graphical representation of signal strength received from each linked Subscriber Unit Click the row in the table to display the...

Page 11: ...the 24VDC power supply Signal Quality Ensure line of sight LOS Check signal strength in web interface 40dB is excellent strength and 80dB is weak Web Interface Plug RJ45 male side of POE directly in to computer and verify network status shows connected Verify the local computer s network settings are in the same IP subnet range as the radio A Connect the opposite end of your Ethernet cable to the ...

Page 12: ...6 QAM 64 QAM 256 QAM Range Line of sight range up to 5 miles for HTA HTS point to point Browser Management Tools QoS Statistics Network Settings Channel Selection Data Security 128 bit AES CCM Operating Environment 40ºC to 70ºC IP66 sealed for outdoor operation die cast aluminum package with rubber gasket seals Mounting Heavy Duty Pole Mount Bracket included Connector 10 100 1000 Ethernet RJ 45 wi...

Page 13: ...ace the defective part at its option at no cost This warranty does not cover defects resulting from misuse or modification of the product If you wish you may purchase extended warranty for this product AvaLAN s XTRa Care Extended Warranty provides a two year extension plus free overnight Continental USA only product replace ment Visit our website for more details Limited Warranty Frequency Channel...

Reviews: