Note: Always lock the clamp before checking the balance with the new tube position!
If
the tube remains stable in a horizontal position when the DEC knob unlocked, the DEC
axis will be balanced.
Tighten the dovetail clamp to firmly lock the telescope tube in its
new position. Do NOT leave the telescope while the dovetail clamp is loose. In the unlikely
event that your telescope should fall off the mount onto the ground, it could ruin your
entire day.
4.2 RA Balancing
Balancing the M-uno mount in the Right
Ascension
axis is different from the other German
Equatorial Mounts, but it is quite easy to do. The balance is performed in two phases, one raw
and the other more precise.
Raw
Balancing
The initial raw balancing must be performed without the
telescope on the mount.
Put the arm of the mount parallel to the ground as seen on
the left picture. Unscrew and set aside the “E” screws
holding the lateral flanges on both sides of the mount.
Loosen but do not remove the D screws on the upper side
just enough to allow the arm to move freely.
©
All Rights reserved
-
17