PAGE 14
The exhaust vent termination on either vertical or horizontal installations shall be located as follows:
•
A minimum of 4 feet (1219 mm) below or beside and a minimum of 1 foot (305 mm) above any door
or window that opens, or any opening into a building.
•
A minimum of 2 feet (610 mm) from any adjacent building.
•
A minimum of 7 feet (2134 mm) above grade, when located adjacent to public walkways.
•
A minimum of 2 feet (610 mm) above grass, plants or other combustible surfaces.
VERTICAL INSTALLATION INTO EXISTING
FACTORY BUILT CHIMNEY
FIGURE 8
NOTE: FOR STANDARD OR CORNER INSTALLATION, STANDARD INSTALLATION SHOWN.
6" Min.
(152mm)
Non-Combustible
Material To Extend
Under The Tee
Optional
Combustion Air
Intake With 90˚
Elbow Or Hood
Tee With
Clean Out Cover
Pellet Vent
3" Min. (76mm)
Pellet Vent To Factory
Built Adaptor Required
Keep Clearance Specified
By Factory Built Chimney
Manufacturer
24" Min. (610mm)
OPTION 2. Firestop With
3" (76mm) Clearance
OPTION 1. Wall Or
Ceiling Thimble
Flashing