Safety
Label
39
© Travis Industries
4101110
100-01256_000
Safety Label
The safety (listing) label is attached under the stove. A copy is shown below.
Report No. 100162727PRT
-001
Control No. 4000515
V
ented Gas
Fireplace Heater
Cypress GS
Certified for USA
and Canada
Tested to:
ANSI Z21.88-2009/CSA
2.33-2009 “V
ented Gas Fireplace Heaters”, CGA
2.17-M91, UL
307b-2006 “Gas
Burning Heating
Appliances for Manufactured Homes”, and CSA
P
.4.1-09.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1/NFP
A 54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA
Z240 MH, Mobile Housing, in
Canada or with the Manufactured Home Constructions and Safety Standard, T
itle 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable,
ANSI/NCSBCS
A225.1/NFP
A 501A, Manufactured Home Installation
Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is
desired, the optional factory conversion kit must be used.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home (USA
only) where not prohibited by local codes. See owner
’s
manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s installation
instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior
. See owner
’s manual
for approved brands of venting.
W
ARNING: Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Refer to the owner
’s information manual provided with this appliance. For assistance or additional information
consult a qualified installer
, service agency or the gas supplier
.
CAUTION:
Hot while in operation. Do Not T
ouch. Severe burns may result. Keep children,
clothing, furniture, gasoline and other liquids having flammable vapors away
. Do not operate
this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be
done by a licensed or qualified service person.
VENTED GAS FIREPLACE HEA
TER - NOT FOR USE WITH SOLID FUEL
MINIMUM CLEARANCES T
O COMBUSTIBLES
Stove T
op to Sidewall
Stove T
op to Backwall
Stove T
op to Cornerwall
Glass Front of Unit
10” (254 mm)
5” (127 mm)
5” (127 mm)
36” (915 mm)
Alcove Min. Height
Alcove Max. Depth
Alcove Min. W
idth
48” (1220 mm)
36” (915 mm)
50-1/8” (1274 mm)
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
40,000
7,400
40,000
11,900
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
11
”
13”
11
”
5.5”
7”
3.5”
For natural gas when equipped with the following drill size orifice: DMS 49 Front - 43 Back
For propane when equipped with the following drill size orifice: DMS 57 Front - 53 Back
This appliance is equipped for use only at altitudes 0-2000 feet (0-610m) in the USA. In Canada, 0-4500 feet (0-1370m).
For altitudes above 2000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s manual for information on making these changes.
Electrical Rating: 1
15V
., 1.5
Amps, 60 Hz
Optional Blower: SKU # 99000173
L.P
.
N.G.
L.P
.
N.G.
2010
201
1
2012
Jan.
Feb.
Mar
.
Apr
.
May
Jun.
Jul.
Aug.
Sep.
Oct.
Nov
.
Dec.
Manufacture
Date: