Optional
Equipment
(for qualified installers only)
45
© Travis Industries
4101110
100-01256_000
9 Replace the regulator following the instructions included with the regulator kit.
Remove and discard the screws (see “a” below) holding the stock regulator in place
(see “b” below). Remove the stock regulator and gasket (see “c” below). Place the
LP regulator in place, making sure the pre-fitted gasket (see”c” below) is in place.
a
T-20 Torx or
Slotted Screwdriver
b
c
d
NOTE: There is a label on the base of the regulator knob indicating regulator type
(NG or LP). Secure the regulator with the screws included with the regulator –
tighten to 25 lb-in of torque. Place the included label on the valve body where it can
be easily seen to insure proper identification (“d”).
NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
10 Restore the appliance to the correct configuration. Make the gas line connection,
bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas
connections and the gas control valve.