Installation (for qualified installers only)
13
© Travis Industries
4151204
100-01430
Vent Requirements
Travis Industries manufactures a
vent kit specifically for this insert
(sku 96200330). It includes 30’
(10M) of vent, hose clamps, and a
prairie cap. The flashing on the cap
is 18” (458mm) by 18” (458mm).
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent
gas appliance must use its own separate vent system.
Make sure the exhaust pipe on the heater connects to the exhaust portion of the cap. The
illustrations below show how the flex liners should be attached.
The exhaust vent must reline the entire length of the chimney and terminate above the chimney top.
Be careful not to crimp or rupture the liner when bending it into chimney offsets.
When installed, the vent must meet all of the vent manufacturer's requirements.
Use the following vent:
3” UL 441 or 1777 Gas Liner for Exhaust and Air Inlet
Duravent Chimney Liner Termination (use one of the two listed below):
-- Prairie Cap with Flashing (included in kit shown above)
-- 3” & 3” Co-Linear to 6-5/8” Co-Axial Adapter, Flashing, & High-Wind Vertical Cap
Altitude Considerations
This heater has been tested at altitudes ranging from sea level to 6,000 feet (1,800 M). In this testing
we have found that the heater, with its standard orifice, burns correctly with just an air shutter
adjustment.
Failure to adjust the air shutter properly may lead to improper combustion which can create a safety
hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Max. Ht. 40' (12.2M)
Min. Ht. 16' (5M)
Exhaust
Max. 2'
(610mm)
offset
Inlet
Summary of Contents for Radiant Plus Small Insert
Page 32: ...32 Operation Travis Industries 4151204 100 01430 Remote Control Operation ...
Page 33: ...Operation 33 Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 34: ...34 Operation Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 35: ...Operation 35 Travis Industries 4151204 100 01430 Remote Control Operation continued ...