16
Installation (for qualified installers only)
© Travis Industries
4151204
100-01430
Vent Configurations
CAUTION:
The “Exhaust Only Re-line” is not covered under the appliance safety standard (ANSI
Z21.88 CSA
2.33
) used in the safety certification of this appliance. The safety certification does not apply to this installation.
Before installing the appliance using this method, contact the Authority Having Jurisdiction to determine if this
installation is acceptable in your area. This type of installation requires a minimum chimney cross section of 48
square inches.
Factory Built (Metal) Wood-
Burning Fireplace
Inlet & Exhaust Re-Line
Exhaust Only Re-Line
Direct Vent Cap
(either high wind or Prairie)
Recommended Block-Off
Plate (must be non-
combustible - metal /
insulation). Prevents odors
from chimney entering
room.
6-5/8" to 3" & 3" Colinear
Adapter & Flashing
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(must be non-combustible -
metal / insulation)
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
Masonry Fireplace
Any cracks or
damage inside the
chimney must be
repaired.
Exhaust
Inlet
Exhaust
Summary of Contents for Radiant Plus Small Insert
Page 32: ...32 Operation Travis Industries 4151204 100 01430 Remote Control Operation ...
Page 33: ...Operation 33 Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 34: ...34 Operation Travis Industries 4151204 100 01430 Remote Control Operation continued ...
Page 35: ...Operation 35 Travis Industries 4151204 100 01430 Remote Control Operation continued ...