background image

AVANSA

®

   

 

 

 

 

              UNINTERUPTIBLE POWER SUPPLY 

 

Pag. 1 

 AVANSA

® 

 

PREMIUM 

 

UNINTERRUPTIBLE POWER SUPPLY 

FOR ELECTRIC AND ELECTRONIC DEVICES 

 

 

 

Pure Sine Wave 

 

300W/500VA-12VDC 
500W/800VA-12VDC 

700W/1000VA-12VDC 

1050W/1500VA-24VDC 

 

User Manual 

Warranty Certificate 

 

 

Summary of Contents for PREMIUM 300W/500VA-12VDC

Page 1: ...LE POWER SUPPLY Pag 1 AVANSA PREMIUM UNINTERRUPTIBLE POWER SUPPLY FOR ELECTRIC AND ELECTRONIC DEVICES Pure Sine Wave 300W 500VA 12VDC 500W 800VA 12VDC 700W 1000VA 12VDC 1050W 1500VA 24VDC User Manual Warranty Certificate ...

Page 2: ...feature of this device is the output power waveform when operating on battery which is pure sine wave identical to the main electricity power network of your house When the main power of your house is ON the UPS will charge your battery ensuring a long lasting battery life The UPS is only working with an external 12V battery or 24V for the 1050W model UPS It should be used only lead acid battery t...

Page 3: ...y connect the main power supply and then connect the consumer to the UPS To start press and hold the power button ON OFF for 4 seconds The operation of the system begins with the automatic detection of the state of the battery and mains voltage If the voltage of the battery is under 10 8V the UPS will consider that the battery is damaged and it will not start If the battery is good and the voltage...

Page 4: ...he UPS is heating up the cooling fan is automatically controlled according to UPS needs you don t need to worry if you hear the fan working even if the battery is fully charged or there is no power consumption the fan is automatically switched on and off depending on the UPS needs Ground The UPS stops if there is leakage current Battery alarm and protection if the battery is discharged to a value ...

Page 5: ...values 50Ah 150Ah Do not use less than 50Ah batteries because the high initial charging current of the UPS up to 10A will reduce the battery life The UPS of 1050W 1500VA will need the use a 24V battery or two 12V batteries connected in serial connection If you use two 12V batteries they should be similar batteries having the same age and the same capacity Below you can find some teoretical values ...

Page 6: ...AVANSA UNINTERUPTIBLE POWER SUPPLY Pag 6 ...

Page 7: ... LCD not working ON button not pushed enough Battery not connected Burned fuse UPS damaged Push ON button over 4 seconds Connect the battery Replace fuse Repair or replace UPS works only on battery Main power cable brocken Burned fuse Main power is under 160V or over 260V UPS damaged Replace cable Replace fuse Contact power supply company Repair or replace Fast beep signal Overload Battery exhaust...