Service and maintenance instructions
700 Series
1
2
6
6
3
3
4
4
7
7
5
1
5
8
8
2
9 9
Light bulbs
Part no. for standard front light bulb and work light bulb is 64874.
Contact Avant service in case the steel structure of the loader gets damaged. A faulty reparation
can cause a dangerous situation.
In case the ROPS safety frame or the FOPS canopy of the machine gets damaged, the machine
must be taken to Avant service for checking. It is not allowed to repair the ROPS and FOPS.
31
GREASING POINTS
Following pictures show the location of greasing points.
1. Lift cylinder, both ends
2. Steering cylinder, both ends
3. Tilt cylinder, both ends
4. Pivot pins on attachment
coupling plate/boom
5. Pivot pin on loader boom
6. Articulation joint
7. Tilting mechanism
8. Leveling cylinder, both ends
9. Telescopic boom, grease with
boom completely retracted
Refueling
Check fuel level and fill the tank if necessary. Use diesel fuel only, in accordance with the instructions in the
Kubota engine Operators Manual. Use of other fuels is not allowed, because their quality and properties
cannot be guaranteed. Make sure not to let the fuel tank get empty. Should this happen, refuel and restart -
the engine is fitted with automatic fuel bleeding.
Do not spill fuel when refueling. should this happen, wipe the fuel away immediately in order
to avoid risk of fire.
Always stop the engine before refueling.
Keep the engine away from open fire. do not smoke during refueling.
Check the tightness of the
pivot pin locking screws, if
loose tighten and use thread
locker.
Metal structures of the loader