Level II Programming
27
Rev C
•
Viewing the Salt Amount
The salt amount is selected by tyour AvantaPure Water Treatment
Professional.
•
Setting Capacity
Softener Default Capacity Setting
The default capacity setting is accurately calculated when the model
number is entered by the factory. The capacity can be changed.
Contact your AvantaPure Water Treatment Professional before
adjusting the capacity setting. Default capacities are shown in Table 1.
•
Setting the Hardness (conditioner only)
Hardness is set in grains per gallon (gpg) or parts per million (ppm) and
should be programmed to the total hardness level of the incoming
water supply. Press the SET button to make the display flash. Use the
UP and DOWN buttons to adjust the hardness setting. Press the SET
button when the desired setting has been reached.
•
Setting the Language
The controller is capable of displaying 6 different languages. They are
as follows:
1 = English
2 = Spanish
3 = French
4 = Italian
5 = Flemish
6 = German
Press the SET button and select the desired language using the UP or
DOWN buttons. Press the SET button to accept the selection.
•
Setting Clock Mode
The controller can be programmed to operate with a 12- or 24-hour
clock. Program the clock mode to "12" for a 12-hour clock or "24" for a
24-hour clock. When the controller is programmed as a 12-hour clock
the PM indicator will illuminate during the PM hours. There is no AM
indicator.
•
Setting Units of Measure
The controller can be programmed to operate in U.S. or Metric units.
Program the Units of Measure to 0 (zero) for U.S. units or 1 for Metric
units.
•
Viewing the Injector Type
The injector is selected by system model number at the factory.
NOTE:
(Conditioners only) A different model number must be selected
to change the default capacity and salt dosage.