14.  If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in 

accordance with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI 
Z223. 1/NFPA 54.

Always follow these lighting and shut down instructions when lighting the rice cooker. A 5 minute complete 
shut off period is required before lighting or relighting pilot. Check for gas leaks before relighting unit. Use 
soapy water or other suitable leak detector. Rinse off the soapy water after testing. 

Notice to the Installer- the following must be performed to insure proper operation.

1. Remove pot, wind shield, and base cover.

2. Turn gas valve to 

ON

 position.

3.  Gently push on the

 THEN COOK

 button. It should stop half way down and not engage. This is a safety 

feature that does not allow accidental start of the main burner unless the warming button has already been 
pushed. 

4.  Push the left button marked 

FIRST IGNITE

 down until the unit clicks, then release it. This is the ignition 

leaver and should light the pilot. The red button labeled 

WARMING

 controls the pilot and is hidden by the 

FIRST IGNITE

 button when off. Pushing the

 FIRST IGNITE 

button also engages the 

WARMING

 button 

and exposes it. It will stay down until pushed up to extinguish the pilot. If the pilot has not lit, repeat until 
the pilot lights. 

5. If the pilot fails to remain lit, refer to 

Trouble Shooting

 on page 13.

6.  Replace the pot, wind shield, and base cover in their proper order. With the pilot lit, push the 

THEN COOK

 

button down to its position without water in the pot, The unit should shut off within 3 to 4 minutes. If it fails 
to shut off , push the 

THEN COOK

 button up to the

 OFF

 position and see 

Trouble Shooting

 on page 13. 

If it shuts off normally, add a gallon of water and wait for the click indicating that the sensor has reset. With 
the pilot lit, press the 

THEN COOK 

button again. The rice cooker should boil the pot dry and the shut off. 

If it fails to shut off normally, press the 

THEN COOK

 button up to it’s off position and refer to the 

Trouble 

Shooting 

section on page 13 for additional causes and remedies.

WARNING

When igniting the pilot, position the jacket window directly over 

FIRST IGNITE

 and 

THEN COOK

 buttons. 

Use caution when igniting pilot and maintain a safe distance from wind shield window. 

SHUT DOWN 

When removing the pot, make sure to push the red

 WARMING

 button up until it clicks and is hidden by the 

FIRST IGNITE

 button- it is then in the 

OFF

 position. A 5 minute complete shut off period is required before 

lighting or relighting the pilot. 

Summary of Contents for 177GRCLP

Page 1: ... not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance Instructions thoroughly before installing or servicing this equipment 5010781 Conforms to ANSI STD Z83 11 2016 Intertek ...

Page 2: ...ctions for future reference Index Safety Precautions 3 Specifications 4 Parts List 4 Safe Usage 5 Placement 5 Installation Instructions 6 7 Before Use 8 Notice 8 9 Instructions 9 10 11 Cleaning Method 12 Maintenance Instructions 12 Troubleshooting 13 Warranty 14 ...

Page 3: ...not block the steam outlet on the cookers lid or exhaust outlet 4 Use a qualified gas pipeline 5 Please do not use gas pipe made of vinyl or rubber 6 When cooker is not in use make sure gas intake valve is closed E Other Special Cases In case you notice any unusual circumstances such as gas combustion are different now strange smell strange noise ect please remain calm immediately turn off gas int...

Page 4: ...er 0 4MM Model No GRCNAT Power Rating 14 000 BTU Capacity 110 cups 55 cups raw Weight 33 6 lb Dimensions 201 4 D x 171 8 H Orifice Size Drill For Main Burner 1 8MM Orifice Size for Permanent Pilot 0 3MM Orifice Size for Ignition Burner 0 6MM Parts List NO PART NAME 1 Water Pan 2 Flame Failure Device 3 Burner 4 Connector 5 Gas Switch 6 Cooking Knob 7 Warming Knob 8 Ignition Knob 9 Bottom Base 10 Wa...

Page 5: ...e NOTE Current national gas types 1 Liquid Propane Gas Y 2 Natural Gas T 3 Manufactured Gas R Placement Keep away from combustible substances Place in area with good ventilation The side and back clearance must be more than 5 9 in The above clearance must be more than 19 68 in Place on a flat surface Avoid placing in humid location to extend life of the unit ...

Page 6: ...it Local safety codes should be complied with in respect to fire hazard avoidance 7 Use of the supplied pressure regulator is mandatory Note that the use of 2 regulators may cause insufficient gas flow Consult with installer but always comply with above codes 8 Keep the appliance area free and clear from combustible materials gasoline and other flammable vapors and liquids 9 Locate the appliance i...

Page 7: ...IGNITE button also engages the WARMING button and exposes it It will stay down until pushed up to extinguish the pilot If the pilot has not lit repeat until the pilot lights 5 If the pilot fails to remain lit refer to Trouble Shooting on page 13 6 Replace the pot wind shield and base cover in their proper order With the pilot lit push the THEN COOK button down to its position without water in the ...

Page 8: ... the hose regularly and change immediately if it becomes compromised Do not place the hose underneath the cooker Notice Failure will occur if the water pan wind shield and inner pot are placed improperly Confirm the following before using for best performance 1 Water pan is placed correctly underneath the bottom Improper placement would cause unsuccessful ignition or flame out NOTE Reversed placem...

Page 9: ...burner dry To avoid incomplete combustion do not cover the top of the rice cooker Stay in proximity when the rice cooker is on This is to avoid gas leakage caused by wind blow off Clean the water in the inner pot to avoid burning It is normal for the color of the aluminum inner pot to change This might be due to water quality insufficient cooking water consecutive cooking or remained rice pulp It ...

Page 10: ... down COOK BUTTON COOK BUTTON goes up automatically when cooking is finished 6 The cooker keeps warm after COOK BUTTON resumes OFF position 7 Pull WARM BUTTON upwards when warming function is not needed 8 Turn gas valve to OFF position If ignition does not occur in 5 seconds turn the burner control s off wait 5 minutes and repeat the lighting procedure The WARM BUTTON is not visible when the unit ...

Page 11: ...t open the lid after the flame is out Wait about 15 to 20 minutes to avoid possible injury NOTE The recommended time for warming rice is one hour Pull the WARM button upwards when warming is not needed Air Adjustment 1 Place the air conditioning plate at the correct position for effective combustion NOTE If combustion is unsuccessful adjust the air conditioning plate until the flame is visible How...

Page 12: ...of the Lid Clean with soap and water Cleaning of Burner Black burner orifice or inset net will cause incomplete combustion In order to have effective combustion clean the burner regularly Please use needle to clean the burner hole to make the flame normal NOTE Do not use water to clean the burner Maintenance Instructions 1 Contact factory the factory representative or a local service company to pe...

Page 13: ...r pan 1 Thermal expansion device replacement 2 Assemble the parts test with the empty pot for 2 3 minutes 1 Use exclusive HVR only 2 Uneven display will cause early switch off watery rice or burned rice Soak the rice for 30 minutes for better performance Wait for 15 20 minutes after the COOK is pulled up to dry moisture in the cooker Water may vary depending on rice texture a e g Water may be redu...

Page 14: ...no event be liable for direct indirect or consequential damages in connection with Avantco commercial products This warranty is not effective if damage occurs because of accident carelessness improper installation lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and operating instructions Work performed by unaut...

Reviews: