Additional Controller Instructions
Setting the set point (desired temperature value)
1. Press
SET for 1 second, the set temperature will start flashing after a few moments;
2. To increase or decrese the temperarture, use the
UP
or
DOWN
button;
3. Press
SET
to confirm new temperature.
Switching the device ON/OFF
Press
UP
for more than 3 seconds. The control and defrost algorithms are now displayed and the instrument
displays the message "OFF" alternating with the temperature read by the set probe.
Placing the device into a manual defrost
Press
DOWN
for more than 3 seconds (the defrost starts only if the temperature conditions are valid).
Placing the device into a continuous cycle
Press
UP
and
DOWN
together for more than 3 seconds.
Accessing and setting type F (frequent) and type C (configuration) parameters
1. Press
SET
for 3 seconds (the display will show "PS");
2. To access the type F and C parameter menu, press
SET
, enter the password "22" using
UP/DOWN
, press
SET
to confirm;
3. Scroll inside the parameter menu using
UP/DOWN
;
4. To set the value of the parameter displayed, press
SET
, then
UP/DOWN
and finally
SET
to confirm the
changes (returning to the parameter menu).
To save all of the new values and exit the parameter menu, press
SET
for 3 seconds;
To exit the menu without saving the changed values (exit by timeout), do not press any button for at least
60 seconds.
19
Summary of Contents for 178A19FHC
Page 9: ...2 WIRING DIAGRAMS 2 1 One door refrigerators SS1RHC SS1RGHC A19RHC A23RHC 6 ...
Page 10: ...7 ...
Page 11: ...2 2 One door freezers SS1FHC A19FHC A23FHC 8 ...
Page 12: ...9 ...
Page 13: ...2 3 Two door refrigerators SS2RHC SS2RGHC A49RHC 10 ...
Page 14: ...11 ...
Page 15: ...2 4 Two door freezers SS2FHC A49FHC 12 ...
Page 16: ...2 5 Three door refrigerator SS3RHC 2 6 Three door freezer SS3FHC 13 ...
Page 17: ...3 PART DETAILS 3 1 Control Panel 3 2 Door 3 3 Shelf Shelf Rails Brackets 14 ...
Page 18: ...3 4 Hinges Upper Hinges Bottom Hinges Hinge Comparison 15 ...
Page 19: ...3 5 Refrigeration System 16 ...
Page 24: ...21 ...
Page 25: ...22 ...
Page 26: ...4 2 Correct Settings for Carel Controllers 23 ...