Troubleshooting
Compressor Not Running
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit breaker.
Power cord unplugged.
Plug in power cord.
Thermostat set too high.
Set thermostat to lower temperature.
Cabinet in defrost cycle.
Wait for defrost cycle to finish.
Condensing Units Run For Long Periods of Time
Excessive amount of warm product placed in cabinet.
Allow adequate time for product to cool down.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
Cabinet Temperature is too Warm
Thermostat set too warm.
Set thermostat to lower temperature.
Excessive amount of warm product placed in cabinet.
Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped.
Replace fuse or reset circuit breaker.
Dirty condenser coil.
Clean the condenser coil.
Evaporator coil iced over.
Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.