background image

 

 

- 23 -

OPTIONS AND FEATURES 

 
 

24.

 

LED Indicator

 

 

 

The LED Indicator (Fig.18-C) is located under the Courtesy Lamp Cover and serves to indicate the 
functions as described in the following tables; 

 

Green LED – Transformer and Battery Powered AGDO 

 

 

Provides visual indication of functionality sequences as described in the following table; 

 

Display 

     Indicator 

Glow Solid  

 

 

 

Reached close limit position. 

Slow Flash  

 

 

 

Reached open limit position. 

Medium Flash    

 

 

Learning or deleting Hand Transmitter codes 

Quick Flash (A Mode)    

 

Learning new drive force parameters 

Quick Flash (M Mode)   

 

Force adjust mode activated 

Sleep 

Mode 

   Intermittent 

Flash 

 

 

Red LED – Battery Powered AGDO only. 

 

 

Provides visual indication of functionality sequence as described in the following table; 

 

 Display 

     Indicator 

 Glows 

Solid 

 

   Battery 

Charger 

inactive 

 

Returns to Green 

 

 

Battery Charger Active 

 

25.

 

Run Button 

 

 

The black “Run” Button (Fig.18-E) is located under the Lamp Cover and serves to initiate the functions as 
described in the following table; 

 

 Function 

    Action 

Activate 

AGDO 

   Momentary 

press 

Safety Beam override     

 

Press and hold until garage door is fully closed 

Sleep Mode 

 

 

 

Press and hold in conjunction with “Learn” Button 

 

26.

 

Safety Beams 

 

 

Genuine 2 wire or aftermarket 4 wire Safety Beams may be connected to the AGDO  

 

The installation of Safety Beams greatly enhances safety by constantly monitoring for persons or objects 
which may pass within the path of the moving garage door. The AGDO will commence to Safety Reverse if 
the Safety Beams become momentarily or permanently interrupted during a Close Cycle. 

 

Mounting 

 

 

 

Locate the Safety Beam mounting brackets provided. 

 

Mark the inside garage door framing so that the bottom edge of the mounting bracket sits 125mm off the 
floor. 

 

Use the 2 mounting screws provided to fasten each mounting bracket to the wall. 

 

Use the 2 screws and nuts provided to fasten the Safety Beams to the mounting brackets so that the indicator 
lamp on each Safety Beam is facing upwards. 

 

Connection 

 

 

Genuine 2 Wire 

 

 

Using the Figure 8 Cable provided - strip back and connect the 2 strands of one end of the cable to each of 
the 2 terminals located on the outer cover of each Safety Beam. 

 

Securely fix the cable up and along the wall and run one length of each cable adjacent to the Control Box.  

 

Strip back and connect one strand of each cable to the Output Terminals “SB2” (Fig.16) 

 
 

Summary of Contents for SDO-21 DP

Page 1: ...1...

Page 2: ...2...

Page 3: ...ustments 12 Engaging Disengaging 12 Door Travel Adjustment 13 Safety Obstruction Force Adjustment 13 Adaptive Mode 14 Manual Mode 15 Options and Features 17 Accessory Connections 17 Auto Close 17 Back...

Page 4: ...ecome rusty over time resulting in additional operating friction between the coils which may cause the AGDO to malfunction b Seasonal temperature changes may cause the garage door springs to expand an...

Page 5: ...lways ensure that the garage door is fully open stationary before driving in or out of the garage 26 Always ensure the garage door is fully closed and stationary before moving out of its view 27 Adjus...

Page 6: ...Rail OR mounted on the ceiling next to Drive Rail OR mounted on side wall of garage optional cable extension kit required Drive Rail supported by Drive Rail Hanger which is mounted flush to the ceili...

Page 7: ...into the Tensioning Block Fig 3B D1 Ensure that the plastic chain insulator ends are fully abutted and form one continuous piece Insert the Terminal Bracket Fig 3 E into the Drive Rail Segment closest...

Page 8: ...8 ASSEMBLY INSTRUCTIONS Sectional Track Type Tip Up assembly depicted Fig 3 Fig 3A Fig 3B...

Page 9: ...tability of the fixing points b Mounting the Drive Rail more than 50mm above the Highest Arcing Point of the garage door may cause the Drive Rail to flex excessively Always ensure that the bottom edge...

Page 10: ...underside of the Drive Rail should be no more than 50mm above the highest arcing point for its entire length Mounting the Drive Rail more than 50mm above the Highest Arcing Point of the garage door m...

Page 11: ...the installer to determine the structural suitability of the fixing points 8 Attaching Towing Arms Close the garage door Remove the Drive Unit cover and insert the Straight Towing Arm through the slot...

Page 12: ...NGAGE pull down on the release handle Fig 10 until a click is felt and then release the handle TO ENGAGE pull down on the release handle once again until a click is felt and then release the handle Im...

Page 13: ...Fig 11 Loosen the Limit Prong Lock Screw by half a turn and slide the Prong towards the Control Box to increase garage door travel and away from the Control Box to decrease travel Re tighten the Limit...

Page 14: ...lash Important Note During initial power up learning the Safety Obstruction Force values of the AGDO default to a maximum setting Encounter a solid obstruction during the course of the initial learnin...

Page 15: ...s The LED Indicator will cease to quick flash once learning has been completed Important Note During a Forced Learn the Safety Obstruction Force values default to a maximum setting Encounter a solid o...

Page 16: ...rotate the green Open Offset Adjustment Pin 5 degrees in the appropriate direction clockwise to increase force anti clockwise to decrease force and then repeat the previous testing steps Safety Obstr...

Page 17: ...ill automatically close the garage door i 3 sec after reaching the open limit point provided that a person or object has passed through the Safety Beams during the open cycle or ii upon expiry of the...

Page 18: ...The Battery Charger provided with Battery Powered AGDO only should be plugged in to a dedicated power supply and remain permanently on A red LED located on the back of the charger will glow solid to...

Page 19: ...ols from which the AGDO may be adjusted and functionality customized to suit individual requirements Most commonly used functionality controls are accessible from within the Courtesy Lamp Cover Less c...

Page 20: ...Note the Control Box Cover can be removed once the head of the screw is protruding by approx 5mm v remove the Control Box Cover by pulling first outwards and then downwards at the finger recess points...

Page 21: ...ntrol Box Covers Refer Sec 18 for removal and replacement details Read through the following table and select the specific functionality best suited your specific personal or garage door requirements...

Page 22: ...smitter button LED Indicator will extinguish v momentarily press the Hand Transmitter button again LED Indicator will begin to quick flash rapidly programming is completed once the LED Indicator cease...

Page 23: ...til garage door is fully closed Sleep Mode Press and hold in conjunction with Learn Button 26 Safety Beams Genuine 2 wire or aftermarket 4 wire Safety Beams may be connected to the AGDO The installati...

Page 24: ...ion If the garage door commences a close cycle but within 1 second stops and reverses check that the Safety Beams are aligned correctly as outlined in Alignment Override In the event of Safety Beam ma...

Page 25: ...imum speed Note Available only when Adaptive Mode has been selected Adjustment To enter Speed Control adjustment mode i move the Drive Unit so that it is positioned mid way between the 2 Limit Adjust...

Page 26: ...late and mounting instructions provided with the switch The Wireless Wall Switch may be learned into be AGDO as per the procedure outlined on Sec 22 Code Learning Important Note The wireless Wall Swit...

Page 27: ...active 18 17 1 Door requires excessive force Check for correct Safety Obstruction Force adjustment settings 13 12 to Safety Reverse Door requires excessive force Check for correct Safety Obstruction F...

Page 28: ...28 NOTES...

Reviews: