- 24 -
OPTIONS AND FEATURES
Aftermarket 4 Wire
Follow Safety Beam manufacturers instructions and connect to the Output Terminals depicted in Fig.13
Important Note: AGDO provides 24VDC output and Normally Open input.
Alignment
Adjust the Safety Beam module marked “Transmitter” (by turning the mounting bracket) so that it is aimed
directly at the lens of the Safety Beam module marked “Receiver”. An indicator lamp located along the top
edge of the “Receiver” will glow green once the correct alignment has been achieved.
Test the Safety Beam alignment several times each time ensuring that when the Safety Beams are obstructed
the green indicator lamp extinguishes and when unobstructed the indicator lamp glows solid.
Firmly tighten the Safety Beam mounting bracket fixing screws.
Installation of the Safety Beams is now complete.
Enabling
Remove the Courtesy Lamp and Control Box Covers to expose the Control Board (Refer Sec.18 for removal
and replacement details)
Select Dip 2 (SB) to the “ON” position (Fig.16)
Replace the Control Box and Courtesy Lamp Covers
Testing
Initiate a close cycle. As the garage door is closing interrupt the Safety Beams by passing an object through
the line of the Safety Beams. If the Safety Beams are functioning correctly the AGDO should stop and then
immediately reverse direction.
If the garage door commences a close cycle but within 1 second stops and reverses, check that the Safety
Beams are aligned correctly as outlined in “Alignment”
Override
In the event of Safety Beam malfunction the can be closed by pressing and holding the black “Run” Button
(Fig.18-E) until such time as the garage door is fully closed and has stopped.
Note: If the black “Run” Button is released prior to the garage door reaching the fully closed position the
AGDO will Safety Reverse.
27.
Safety Reverse
In the event that the garage door encounters a sufficient obstruction during a close cycle the AGDO will
immediately stop and then begin to reverse direction. (Safety Reverse) The degree of Safety Reverse may be
selected as follows;
a.
Full Safety Reverse
– the AGDO will reverse to the fully open position. (Not available with battery
powered AGDO)
b.
Partial Safety Reverse
– the AGDO will reverse and then stop after 3 sec. Partial Safety Reverse
ensures that the garage door does not open fully and thereby present an unwanted security risk. Upon
receiving a Signal immediately subsequent to partial Safety Reverse the AGDO will recommence
movement in the open direction.
Enabling
i.
Remove the Courtesy Lamp and Control Box Covers to expose the Control Board. (refer Sec.18 for
removal and replacement details)
ii.
Full Safety Reverse – select Dip 6 (PR) to “OFF” (Fig.16)
iii.
Partial Safety Reverse – select Dip 6 (PR) to “ON” (Fig.16)
iv.
Replace the Control Box and Courtesy Lamp Covers once selection has been completed.