IMPORTANT SAFETY RECOMMENDATIONS 

 

 

15.

 

Subsequent to installation and adjustment, the AGDO the garage door 

must 

stop and

 reverse direction when 

it comes into contact with a 35mm high solid object placed on the floor under the garage door.

 

16.

 

The correct function of the Safety Obstruction Force System should be checked on a monthly basis. 

 

17.

 

Never use the AGDO unless the garage door is in full view and free from any object which may impede the 
movement of the garage door such as cars, children and / or adults.

 

18.

 

Never allow children to operate the AGDO. 

19.

 

Never operate the AGDO when any persons are under or near the path of the garage door. Children 

must

 be 

supervised at all times when near the garage door and when the AGDO is in use. 

20.

 

Never attempt to disengage the AGDO to manual operation when there are children / persons and / or solid 
objects including motor vehicles under or near the path of the garage door as the garage door may fall sharply 
upon Manual Release from the AGDO. 

21.

 

Never attempt to open or close the garage door by pulling on the Engage / Disengage Cord. 

22.

 

Never attempt to make any repairs or remove covers from the AGDO without first disconnecting the power 
supply cord from main power supply. 

23.

 

Removal of the AGDO’s protective covers must only be performed by a technically qualified person. 
Attempting to remove the protective covers or repair the AGDO without suitable technical qualification may 
result in severe personal injury, death and / or property damage. 

24.

 

For additional safety we strongly recommend the inclusion of Safety Beams. Although the AGDO 
incorporates a pressure sensitive Safety Obstruction Force system the addition of Safety Beams will greatly 
enhance the operating safety of an automatic garage door and provide additional peace of mind. In some

 

countries it is a mandate of law to fit Safety Beams. It is the sole responsibility of the owner / installer to fit 
Safety Beams in those countries that so require.

 

25.

 

Always ensure that the garage door is fully open & stationary before driving in or out of the garage. 

26.

 

Always ensure the garage door is fully closed and stationary before moving out of its view. 

27.

 

Adjustments to the Safety Stop / Reverse Force settings must only be carried out by a technically qualified 
person. Attempting to adjust the settings without suitable technical qualification may result in severe personal 
injury, death and / or property damage. 

28.

 

Keep hands and loose clothing clear of the AGDO and garage door at all times. 

29.

 

In order for the Safety Obstruction Force system to function it must first encounter an obstruction in the form 
of an object / person on to which some force 

MUST

 be exerted. As a result the object / person / garage door 

may suffer 

DAMAGE AND / OR INJURY.

 

30.

 

The Safety Obstruction System is designed to work on STATIONARY objects only. Serious personal 
injury, death and / or property damage may occur if the garage door comes into contact with a moving 
object during an open or close cycle 

 

 

Warranty Exclusions 

 

No claims whatsoever will be recognized under the terms of the AGDO’s warranty

 

which pertain to 

damage, injury, cost or expense, suffered by persons and / or to property, which either directly or 
indirectly arise out of any one of the following occurrences; 
 

i.

 

Failure to install the AGDO in accordance with the captioned instructions.

 

ii.

 

The garage door coming into contact with a moving object. (refer Point 30 in the above)

 

iii.

 

The AGDO being used for other than a maximum 4 car residential application.

 

iv.

 

Installing the AGDO on an improperly balanced and / or poorly functioning and / or misaligned 
garage door. (refer Point 3 in the above)

 

v.

 

Failure to adequately lubricate the garage door counter balance springs. (refer point 6 in the 
above)

 

vi.

 

Failure to adequately fix the GDO to the garage structure

 

vii.

 

Attempting to open or close the garage door by pulling directly on the Manual Release Cord.

 

viii.

 

Manually releasing the garage door in any position other than when it is fully closed.

 

ix.

 

Failure to connect the AGDO to a properly earthed power supply

 

x.

 

Note: Light bulb failures are not covered under the terms of this product’s warranty

 

 
 

Summary of Contents for SDO-21 DP

Page 1: ...1...

Page 2: ...2...

Page 3: ...ustments 12 Engaging Disengaging 12 Door Travel Adjustment 13 Safety Obstruction Force Adjustment 13 Adaptive Mode 14 Manual Mode 15 Options and Features 17 Accessory Connections 17 Auto Close 17 Back...

Page 4: ...ecome rusty over time resulting in additional operating friction between the coils which may cause the AGDO to malfunction b Seasonal temperature changes may cause the garage door springs to expand an...

Page 5: ...lways ensure that the garage door is fully open stationary before driving in or out of the garage 26 Always ensure the garage door is fully closed and stationary before moving out of its view 27 Adjus...

Page 6: ...Rail OR mounted on the ceiling next to Drive Rail OR mounted on side wall of garage optional cable extension kit required Drive Rail supported by Drive Rail Hanger which is mounted flush to the ceili...

Page 7: ...into the Tensioning Block Fig 3B D1 Ensure that the plastic chain insulator ends are fully abutted and form one continuous piece Insert the Terminal Bracket Fig 3 E into the Drive Rail Segment closest...

Page 8: ...8 ASSEMBLY INSTRUCTIONS Sectional Track Type Tip Up assembly depicted Fig 3 Fig 3A Fig 3B...

Page 9: ...tability of the fixing points b Mounting the Drive Rail more than 50mm above the Highest Arcing Point of the garage door may cause the Drive Rail to flex excessively Always ensure that the bottom edge...

Page 10: ...underside of the Drive Rail should be no more than 50mm above the highest arcing point for its entire length Mounting the Drive Rail more than 50mm above the Highest Arcing Point of the garage door m...

Page 11: ...the installer to determine the structural suitability of the fixing points 8 Attaching Towing Arms Close the garage door Remove the Drive Unit cover and insert the Straight Towing Arm through the slot...

Page 12: ...NGAGE pull down on the release handle Fig 10 until a click is felt and then release the handle TO ENGAGE pull down on the release handle once again until a click is felt and then release the handle Im...

Page 13: ...Fig 11 Loosen the Limit Prong Lock Screw by half a turn and slide the Prong towards the Control Box to increase garage door travel and away from the Control Box to decrease travel Re tighten the Limit...

Page 14: ...lash Important Note During initial power up learning the Safety Obstruction Force values of the AGDO default to a maximum setting Encounter a solid obstruction during the course of the initial learnin...

Page 15: ...s The LED Indicator will cease to quick flash once learning has been completed Important Note During a Forced Learn the Safety Obstruction Force values default to a maximum setting Encounter a solid o...

Page 16: ...rotate the green Open Offset Adjustment Pin 5 degrees in the appropriate direction clockwise to increase force anti clockwise to decrease force and then repeat the previous testing steps Safety Obstr...

Page 17: ...ill automatically close the garage door i 3 sec after reaching the open limit point provided that a person or object has passed through the Safety Beams during the open cycle or ii upon expiry of the...

Page 18: ...The Battery Charger provided with Battery Powered AGDO only should be plugged in to a dedicated power supply and remain permanently on A red LED located on the back of the charger will glow solid to...

Page 19: ...ols from which the AGDO may be adjusted and functionality customized to suit individual requirements Most commonly used functionality controls are accessible from within the Courtesy Lamp Cover Less c...

Page 20: ...Note the Control Box Cover can be removed once the head of the screw is protruding by approx 5mm v remove the Control Box Cover by pulling first outwards and then downwards at the finger recess points...

Page 21: ...ntrol Box Covers Refer Sec 18 for removal and replacement details Read through the following table and select the specific functionality best suited your specific personal or garage door requirements...

Page 22: ...smitter button LED Indicator will extinguish v momentarily press the Hand Transmitter button again LED Indicator will begin to quick flash rapidly programming is completed once the LED Indicator cease...

Page 23: ...til garage door is fully closed Sleep Mode Press and hold in conjunction with Learn Button 26 Safety Beams Genuine 2 wire or aftermarket 4 wire Safety Beams may be connected to the AGDO The installati...

Page 24: ...ion If the garage door commences a close cycle but within 1 second stops and reverses check that the Safety Beams are aligned correctly as outlined in Alignment Override In the event of Safety Beam ma...

Page 25: ...imum speed Note Available only when Adaptive Mode has been selected Adjustment To enter Speed Control adjustment mode i move the Drive Unit so that it is positioned mid way between the 2 Limit Adjust...

Page 26: ...late and mounting instructions provided with the switch The Wireless Wall Switch may be learned into be AGDO as per the procedure outlined on Sec 22 Code Learning Important Note The wireless Wall Swit...

Page 27: ...active 18 17 1 Door requires excessive force Check for correct Safety Obstruction Force adjustment settings 13 12 to Safety Reverse Door requires excessive force Check for correct Safety Obstruction F...

Page 28: ...28 NOTES...

Reviews: