8. TROUBLESHOOTING
8.1. INTRODUCTION
CAUTION!
ALL TROUBLESHOOTING OPERATIONS MUST BE CARRIED OUT WITH THE BURNER
SWITCHED OFF.
PROBLEM
CAUSE
SOLUTION
THE START BUTTON
IS PRESSED ON THE
CONTROL PANEL
BUT THE BURNER
DOES NOT START.
The spark does not
strike.
• Flat batteries
under the start
button.
• Replace the batteries (see par. 7.5.3);
• Check that the spark does not disperse along the path of the
white wire.
THE SPARK
STRIKES BUT THE
FLAME DOES NOT
IGNITE
• Check that all the gas system valves between the burner and
counter are open, including the safety solenoid valves.
Disassemble the burner and:
• Clean it: turn it over and, if necessary, blow compressed air
from the air intake and flame breaker.
• Check that the white power cable is intact.
• Check the integrity and correct positioning of the ignition
electrode; if cracked, order a spare kit and replace the
electrode.
•
Eventually, order a new pilot flame assembly and replace it.