CHAPTER 9
Instructions, use and maintenance manual
D r a g o P 1
Page 93
9. ATTACHMENTS
This chapter contains the documentation enclosed with the line.
The enclosed documentation constitutes an integral part of the "INSTRUCTIONS, USE AND MAINTENANCE
MANUAL" of the machine supplied by
AVANZINI BRUCIATORI s.r.l.
It must be used as a reference for the use, operation and maintenance of the equipment and components.
9.1. TECHNICAL DATA SHEET
MODEL
HEATING CAPACITY
in Kw
in Kcal/h
in BTU
MIN
MAX
MIN
MAX
Drago P1
NATURAL GAS
7
15
6020
13.000
23.873
51.553
Drago P1
LPG
7
15
6020
13.000
23.873
51.553
MODEL
GAS
PRESSURE
GAS
VOLUME
GAS
CONNECTION
WEIGHT
in mbar
in Nm3 /h
in inches
in Kg
MIN
MAX
MIN
MAX
Drago P1
NATURAL GAS
15
25
0,74
1,58
½”
4
Drago P1
LPG
25
50
0,25
0,54
½”
4