Troubleshooting via System Status Menu
Issue 6, January 2011
31
6.1
Error Status
The
Error Status
screen displays any alarms that indicate some system malfunction. Some
of these alarms are easily remedied and others require a call to Avaya’s Customer Support
Department.
From the
System Status Menu,
select
Error Status
. The screen displays active alarms on the
Avaya Voice Priority Processor.
The following table displays the list of alarms and a description of the action to take to
eliminate the alarm.
Alarm Text
Action
Maximum payload usage reached
Reduce usage, clear alarm
3
Maximum telephone usage reached
Reduce usage, clear alarm
Maximum access point usage reached
Reduce usage, clear alarm
Maximum call usage reached
Reduce usage, clear alarm
SRP audio delayed
Reduce usage, clear alarm
SRP audio lost
Reduce usage, clear alarm
No IP address
Configure an IP address
AVPP Server(s) lost
Reduce usage or replace lost AVPP Server.
Clear alarm
Press C to clear all clearable alarms.
3
If capacity problems persist, additional AVPP servers may need to be added to the system to improve performance.