Value
Description
This information applies only to second generation modules.
FPGA
Specifies the temperature of the FPGA sensors. A
value of -- indicates that this sensor is not available
on this slot.
FA
Specifies the temperature of the FA sensor, located
on the slice. A value of -- indicates that this sensor is
not available on this slot.
Slice-1 through Slice–3
Specifies temperature information for sensors on
each slice. Sensors provide temperature information
for various datapath components.
Highest Temp
Specifies the highest temperature of all the FPGA or
FA sensors located on this I/O module.
Lowest Temp
Specifies the lowest temperature of all the FPGA or
FA sensors located on this I/O module.
Alarm Threshold
Specifies the FPGA or FA temperature, when
exceeded by one degree, that causes an alarm.
Shutdown Threshold
Specifies the FPGA or FA temperature, when
exceeded by one degree, that causes the system to
shutdown the module by removing power from the
slot.
Virtual Services Platform 9010 show sys-info output
On the Virtual Services Platform 9010, you can see the zone alarm information under the Fan Trays
Info section of the command output for the
show sys-info
command. The following output
displays on a Virtual Services Platform 9010 without a second generation module:
Fan Trays Info :
Zone Info :
FRONT zone :
Mode : NORMAL
Mode Status : Normal
Highest Temperature : 37 C
Extended Zone :
FPGA Highest Temperature : --
FA Highest Temperature : --
REAR zone :
Mode : NORMAL
Mode Status : Normal
Highest Temperature : 0 C
Fan Info :
Tray CardType Serial# Part#
FAN 1 9010CM EC1411012-E6
FAN 2 9010CM EC1411012-E6
Zone Tray Unit Status
FRONT FAN 1 1 OK
FRONT FAN 1 2 OK
FRONT FAN 1 3 OK
FRONT FAN 1 4 OK
FRONT FAN 2 1 OK
Virtual Services Platform 9010
March 2015
Installing Cooling Modules in Avaya VSP 9000
19