2. Navigate to
Devices
>
Devices by Type
>
ASBCE
.
3. Click
Add
.
4. On the Add ABSCE page, do the following :
a. In
Name
, enter a name for the Avaya SBCE server.
b. In
IP Address
, enter any of the Avaya SBCE IP addresses.
c. In
Location
, select the location of the Avaya SBCE server.
5. Click
OK
.
6. Select the Avaya SBCE name from the list and do the following:
a. In
Listen/Relay Internal IP
, enter the Avaya SBCE IP address of the internal A1
interface configured for the load balancer and for STUN/TURN interface.
For more information, see
Configuring Avaya SBCE load monitoring
on page 121 and
WebRTC client side TURN configuration
b. In
Port
, enter
3478
.
c. In
Listen/Relay Public IP
, enter one of the following Avaya SBCE public IP
addresses of the STUN/TURN interface:
• The IP address of the external B1 interface.
• The firewall NAT public IP address of the external B1 interface.
For more information about the B1 interface, see
d. In
Port
, enter
3478
.
e. In
Internal SIP IP
, type the FQDN or IP address of the internal A1 interface of the
Avaya SBCE that is used for SIP signaling.
For more information about interaction with Avaya Aura
®
native clients media configuration
on page 128.
f. In
SIP Protocol
select
TLS
.
g. In
SIP Port
, enter
5061
.
h. In
Local HTTP IP
, enter the internal A1 address configured for the load monitoring
entry.
For example,
asbce_management.company.com
.
i. In
HTTP protocol
, select
https
.
j. In
HTTP port
, enter
443
.
7. Click
OK
.