Troubleshooting
Troubleshooting ATM
192
Maintenance Procedures
December 2003
Figure 48: A500: show signaling stats a1.2 qsaal screen
NOTE:
If there is no connection between the TN230X and the A500 at the Q.SAAL protocol
layer, then no report is displayed.
— If
Port A1.2
(or the port of interest) is
not configured for UNI signaling
,
then the port was administered for no UNI signaling (admin link command). Use the
show signaling summary command to verify that
Signaling
is
UNI3.1
.
— The
Supported only for UNI 3.0
line for the
SDP PDUs:
field means that the
port was administered for UNI3.0 signaling (admin link command). Use the show
signaling summary command to verify that
Signaling
is
UNI3.1
.
— The
POLL PDUs
and
STAT PDUs
counters should be increasing if the TN230X is
actively sending and receiving Q.SAAL Protocol Data Units with the A500. This occurs
even if the TN230X did not achieve board insertion.
Q.93B (network) layer
Are connection requests being received by A500 Call Control?
1
Enter show signaling stats port q93b (or the port of interest) on the A500 console.
A500:show signaling stats A1.2 q93b,
on page 193 shows the screen output.
A500: show signaling stats a1.2 qsaal
------------------------Q.SAAL Statistics------------------------
Port A1.2:
----------
Type: UNI3.1
VPI: 0x00, VCI: 0x05
Tx Rx
-------- --------
BGN PDUs: 0 1
BGAK PDUs: 1 0
END PDUs: 0 0
ENDAK PDUs: 0 0
RS PDUs: 0 0
RSAK PDUs: 0 0
BGREJ PDUs: 0 0
SD PDUs: 81 78
SDP PDUs: Supported only for UNI 3.0
ER PDUs: 0 0
POLL PDUs: 6259 5720
STAT PDUs: 5720 6259
USTAT PDUs: 0 0
ERAK PDUs: 0 0
Discarded PDUs: 0 0
Errored PDUs: 0 0
Buffers in use: 0 0
High buffer mark: 3 0