Troubleshooting
Troubleshooting ATM
194
Maintenance Procedures
December 2003
Figure 50: A500:show signaling cause 31
4
At the S8700 Multi-Connect SAT type display errors, and press
Enter
.
Set the
Error List
to errors and
Category
to PNC on the input screen (
Multi-Connect display errors input screen,
on page 194), and press
Enter
to display any cause
codes (see following
Table 62, Observed cause codes,
on page 195) returned from the ATM
network to a TN230X on the PPN (and to a TN230X in a PN). This is successful only if the links
between the PPN and the PN remain up so that the message from the PN is logged.
Refer to
for detailed information about cause codes for this
MO.
Figure 51: S8700 Multi-Connect display errors input screen
Figure 52, Screen output for display errors command,
on page 195 shows the screen output for the
display errors command.
A500:show signaling cause 31
Cause 31: Normal, unspecified
display errors Page 1 of 1 SPE A
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: Error List: errors
REPORT PERIOD
Interval: a From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category: PNC
Extension:
Trunk ( group/member ): /
Summary of Contents for CMC1
Page 1: ...Maintenance Procedures 555 245 103 Issue 1 1 December 2003 ...
Page 14: ...Contents 14 Maintenance Procedures December 2003 ...
Page 416: ...Additional maintenance procedures IP Telephones 416 Maintenance Procedures December 2003 ...
Page 426: ...Index X 426 Maintenance Procedures December 2003 ...