Maintenance Procedures
315
December 2003
8
In the Restore ASM Configuration section, click Browse. See
on page 315 for an example of the restoring ASM configuration window.
Figure 94: Restoring ASM configuration
9
Click the saved configuration file that you want to restore and click Open.
The file will appear in the box.
10
Click Restore Configuration. A progress window shows the status of the restore.
A confirmation window opens when the update is completed.
11
Click OK to restart the RSA.
12
Click OK to close the current browser window.
Upgrading the RSA firmware
After installing the new RSA board, you must ensure that its firmware version is compatible with the
release of Communication Manager running on the S8500 Media Server. This might involve upgrading
the RSA firmware to the latest version. Before that you must first use these two procedures:
•
Checking the firmware version on the new RSA
•
Checking for the compatible firmware version
Checking the firmware version on the new RSA
To check the version of firmware on the new RSA
1
Log into the RSA card through a browser window.
2
Select Server > Monitors > System Health > Vital Product Data.