Maintenance strategy
G700 server-controlled maintenance
Maintenance Procedures
57
December 2003
Maintenance features for the G700
Table 29, Maintenance features for Avaya G700 Media Gateway,
on page 57 specifies maintenance
features as they apply to the Avaya G700 with the S8300 Media Server.
Table 29: Maintenance features for Avaya G700 Media Gateway
Supported feature
Controller
S8700/
S8500
S8300
Notes
Attendant Console
alarm LED and alarm
report
acknowledgement
LED
Yes
Status of G700 alarms is not available on the
Attendant Console with a legacy controller.
Automatic Trunk
Measurement System
(ATMS)
No
Not available for analog trunks terminating on a
Media Module.
DS0 Looparound
connection
No
DS1 CPE Loopback
Yes
Test is controlled by the DS1 Media Module.
DS1 Synchronization
No
Timing sync is local to the G700 so DS1 sync is
controlled by the G700.
Enable/Disable
Media Module tests
Yes
Enable/Suspend
alarm origination
No
Not supported by S8700 platform.
Environment tests
and alarms for S8300
Not available for S8300 in R1.
ISDN loop around
connection
Yes
ISDN test call
No
Not available for ISDN trunks terminating on a DS1
Media Module.
LED tests
Partial
Works with Media Module LEDs but not with the
G700 alarm LED.
System Configuration
Maintenance Object
No
Not needed for Media Module board insertion.
Indicates that a board is present but that the board
does not respond to a query for board type.
System Link test for
PRI control link for
ISDN DS1 Media
Module
No
Layer 2 of a PRI link is terminated in the G700, so
this does not apply to the G700 with a S8300 Media
Server. A new MO is added for the status and
alarming of H.248 links.
(1 of 2)