Installation - Page 23
DECT - Installation Manual
Page 23
38HBKD0001SAH – Issue 14 (27th October 2003)
Base Station Cable Measurement
Base Station Cable Measurement
The cable distance between the Control Unit and the Base Stations
introduce signal delays for which the system must adjust. Whenever a
Base Station is added or moved, a process of measuring the cable delays
must be performed.
Measuring cable delays
Note:
During this process all the handsets lock for a few minutes and the
system will do a reset.
1. Start
CCFP
.
2. Select
Options
and then
Preferences
.
3. Click on the
Base Station Status
tab.
4. The page shows the current status of the base stations and the
measured cable delays. Options exist to select and measure specific
cable delays or to select and measure all cable delays.
5. To re-measure selected cable delays, tick the appropriate box and
click on
Measure RFP Cable Delay (Chosen)
. To re-measure the all
cable delays click on
Measure RFP Cable Delay (All)
.