Page 70 - Appendices
Page 70
DECT - Installation Manual
Summary of Installing a New System
38HBKD0001SAH – Issue 14 (27th October 2003)
Summary of Installing a New System
1. Install the Control Unit:
Cables 2m maximum from power supply, 5m maximum from MDF. Allow
200mm clearance on all sides. Fix mounting bracket to wall using four
No.6 screws and suitable fixings. Hang cabinet on bracket.
2. Install the DECT Expansion Board:
(optional)
Remove cabinet cover (four screws on base, two one either side). Insert
support pillars onto motherboard and then plug in expansion board.
Connect integral lead to position over existing socket.
3. Install the DECT Alog Boards:
Install into cabinet and connect to MDF using 25-way female D-type cable.
Channel
Pin - Wire Pair
Channel
Pin - Wire Pair
Channel 0
14 - White/Blue
01 - Blue/White
Channel 4
20 - White/Slate
07 - Slate/White
Channel 1
15 - White/Orange
03 - Orange/White
Channel 5
21 - Red/Blue
09 - Blue/Red
Channel 2
17 - White/Green
04 - Green/White
Channel 6
22 - Red/Orange
23 - Orange/Red
Channel 3
18 - White/Brown
06 - Brown/White
Channel 7
24 - Red/Green
12 - Green/Red
4. Connect PC for Programming:
– Install CCFP Admin and SIO if necessary.
5. Install Base Stations:
–
Connect from Control Unit to MDF:
Use cable with 25-way male D-
type.
Base Station
Pin - Wire Base
Station
Pin - Wire
Station 0 (8)
01 - White/Blue
14 - Blue/White
Station 4 (12)
05 - White/Slate
18 - Slate/White
Station 1 (9)
02 - White/Orange
15 - Orange/White
Station 5 (13)
06 - Red/Blue
19 - Blue/Red
Station 2 (10)
03 - White/Green
16 - Green/White
Station 6 (14)
07 - Red/Orange
20 - Orange/Red
Station 3 (11)
04 - White/Brown
17 - Brown/White
Station 7 (15)
08 - Red/Green
21 - Green/Red
–
Connect from MDF to Slave Jack Sockets:
Connect to pins 3 and 4.
–
Mount Base Stations:
Use two No. 6 screws 130mm apart
horizontally.
6. Configure Database:
– Run CCFP Administration.
– Alter the settings for all IWU cards.
– Perform a cable delay measurement.
– Setup the handset details and allow subscription.
7. Subscribe Handsets:
–
Subscribe each handset:
Press
MENU
and then
ENTER
.
– Use
>
to select
SUBSCRIBE
and then press
ENTER
.
– Use
>
to select
CREATE
and then press
ENTER
.
– When system ID is shown, press
ENTER
twice.
8. INDeX Level 8+ DECT Integration
– Set the port type of the two-wire ports to DECT.
– Connect the integration cable between the DCU and INDeX.
– Set the INDeX port speed to 19200.
– Start the DECT log running on the INDeX.