Explosive Atmosphere Telephone
Model EA401
Installation & Operation
WARNING
FIELD REPAIR NOT POSSIBLE. FOR SERVICE RETURN TO FACTORY. TO PREVENT
IGNITION OF HAZARDOUS ATMOSPHERE, DISCONNECT FROM THE SUPPLY CIRCUIT
BEFORE OPENING OR REPLACING FUSE. KEEP TIGHTLY CLOSED WHEN CIRCUITS
ARE ALIVE. ALL CONDUIT RUNS MUST BE SEALED WITHIN 18 INCHES (450 mm) OF
THIS ENCLOSURE. BREAKING OF REAR BOLT SEALS VOIDS MANUFACTURER'S
WARRANTY. SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY.
ATTENTION
CET APPAREIL NE PEUT ETRE REPARE A PIED D'OEUVRE. NE PAS L'OUVRIR.
LES BOULONS DOIVENT ETRE BIEN SERRES DEBRANCHE LE TELEPHONE
AVANT LE REMPLACEMENT DU FUSIBLE. RETOURNER L'APPAREIL A L'USINE
POUR LE DEPANNAGE. LE FAIT DE BRISER LE SCEAU DU FABRICANT A
L'ARRIERE DE L'APPAREIL ANNUELE LA GUARANTIE DU FABRICANT.
Industrie Canada
Industry Canada
1012 4339 A
TELEPHONE FOR USE IN HAZARDOUS LOCATIONS
MOD. NO.: EA401
FUSE: 0.25A 48VDC - TYPE 2AG, FAST-ACTING
REFER TO USER GUIDE FOR INSTALLATION
RECEPTACLE PROVIDES
SER. NO.
COMCODE: 700302045
RELAY CONTACTS
LR65547
INTRINSICALLY SAFE OUTPUT
10A 1/3HP 240V AC
10A 1/3HP 120V AC
10A 30V DC
HANDSET WITH THIS TELEPHONE
MADE IN CANADA
USE ONLY MODEL EA10H
Associated equipment
Appareillage Connexe
[Exia]
CLASS I ZONE 1, GROUPS IIB+H2
ENCLOSURE TYPE 4
CLASS I GROUPS B, C, & D
CLASS II GROUPS E, F, & G