RTP statistics
Issue 1 January 2008
905
rtp-stat min-stat-win
Use the
rtp-stat min-stat-win
command to set the minimum statistic window for the RTP
statistics application. The minimum statistics window is the minimum number of observed RTP
sequence increments for which the application evaluates packet loss. Use the
no
form of this
command to reset the minimum statistic window to its default value.
The VoIP engine evaluates the current received packet loss every RTCP interval. The RTCP
interval is usually between 5 and 8 seconds. The VoIP engine postpones loss estimation to the
next interval if the number of received packets is less than the minimum statistic window.
Syntax
[no] rtp-stat min-stat-win
packets
Parameters
User Level
read-write
Context
general
Example
To set the minimum statistic window to 50:
G450-001(super)# rtp-stat min-stat-win 50
Related Commands
,
Parameter
Description
Possible
Values
Default
Value
packets
The minimum number of observed RTP
sequence increments for which the
application evaluates packet loss