USP configuration
Issue 1 January 2008
1171
Related Commands
ignore dcd
Use the
ignore dcd
command to specify how the system monitors the line to determine if it is
up or down. Specify
ignore dcd
to ignore DCD signals, and instead use DSR/CTS signals to
determine the line’s status. Use the
no
form of the command to specify that DCD signals are
used to determine line status.
Syntax
[no] ignore dcd
User Level
read-write
Context
interface:Serial (USP FR-L2, USP PPP-L2, USP PPP L2-L3)
Example
To ignore DCD signals on an interface:
G450-001(if:Serial 3/1:1)# ignore dcd
Related Commands
invert txclock
Use the
invert txclock
command to invert the transmit clock signal from the data
communications equipment (DCE). Use the
no
form of the command to restore the signal to not
inverted.
Syntax
[no] invert txclock
User Level
read-write