CLI Commands
Object tracking
598 Avaya G450 CLI Reference
Related Commands
frequency
Use the
frequency
command to specify how often an RTR operation should send probes. Use
the
no
form of this command to restore the frequency value to the default.
Note:
Note:
You must run the
type
command to define the RTR operation’s probing method
and the IP address of the remote device before you can use the
frequency
command.
Syntax
[no] frequency
frequency-value
[seconds | milliseconds]
Parameters
User Level
read-write
Context
rtr, rtr type
Example
To set the frequency value for RTR 1 to 20 seconds:
G450-001(config-rtr icmp 1)# frequency 20 seconds
Parameter
Description
Possible Values
Default Value
frequency-value
A number indicating the
frequency of RTR probes
1-60
seconds
or
1000-60,000
milliseconds
5
seconds
or
5000
milliseconds
seconds
Keyword specifying to set the
frequency of RTR probes in
units of seconds
milliseconds
Keyword specifying to set the
frequency of RTR probes in
units of milliseconds