Installing a New G700 without an S8300
212 Installation and Upgrades for Avaya G700 Media Gateway and Avaya S8300 Media Server
Determining which firmware to install on the G700
Conduct the following procedure to compare software versions running on the G700 processors
and media modules with the versions in you planning documents. If the versions do not match,
you need to install the new firmware for those components.
To determine if new firmware for the P330 stack processor is necessary
1. At either the P330-1(super)# or P330-1(configure)# prompt, type
dir
.
The system displays the directory list of software for the P330 stack processor.
Directory list for P300 stack processor
2. Check the version number (ver num) of the EW_Archive file to see if it matches the Release
Letter.
If not, you must upgrade the P330 stack processor.
3. Type
show image version
The system displays the list of software.
Show image version List for P330 stack processor
4. Check the version number of the stack software image file in Band B to see if it matches the
your planning document.
If not, you must upgrade the P330 stack processor.
To determine if new firmware is required for the MGP, VoIP module, and installed
media modules
1. Type
session mgp
M# file
ver num file type
file location
file description
-- ----
------- ----------
-------------
----------------
1 module-config N/A
Running
Conf Ram
Module
Configuration
1 stack-config
N/A
Running
Conf Ram
Stack
Configuration
1 EW_Archive
4.0.4
SW Web Image NV-Ram
WEB Download
1 Booter_Image
3.2.5
SW BootImage NV-Ram
Booter Image
Mod Module-Type Bank Version
------ ----------- ---- -------
3 Avaya G700 media gateway
A 0.0.0
3 Avaya G700 media gateway
B
4.0.17