On-site Preparation for the Upgrade
Issue 7 January 2005
327
2. Log in as craft or dadmin.
3. Enter w2ktt for the Terminal Type (if you are running Windows 2000 on your laptop).
4. Accept the default (
y
) for Suppress Alarm Origination.
Completing pre-upgrade tasks — If the target S8300 is the primary
controller
If the S8300 is configured as an LSP, skip to
Upgrade the S8300
on page 343.
!
CAUTION:
CAUTION:
If you are upgrading an S8300 primary controller that has LSPs registered to it,
the LSPs must be upgraded before the primary controller. (You can use the SAT
command,
list media-gateway
, to see if there are LSPs registered to the
S8300.)
Perform the following procedures if you are upgrading an S8300 that is configured as a primary
controller:
●
To clear alarms
●
To check link status
●
To record all busyouts
●
To disable scheduled maintenance
●
To check for translation corruption
●
To save translations
●
To stop Communication Manager on an LSP
●
To disable alarm origination
Note:
Note:
It is no longer necessary to disable Terminal Translation Initialization (TTI) before
an upgrade or to enable it after an upgrade.
To clear alarms
1. On the Maintenance Web Interface under Alarms, click Current Alarms.
2. If no alarms are listed, skip the next two steps.
3. If alarms are listed, click Clear All.
4. Resolve any remaining major alarms through the Communication Manager SAT.