Installation and wiring of telephones and power supplies
Issue 7 January 2005
393
To connect the 1152A1 PDU
!
CAUTION:
CAUTION:
The 1152A1 PDU has no ON/OFF switch. To connect or disconnect power to the
1152A1 PDU, simply insert or remove the power cable from the AC power
receptacle on the rear of the 1152A1 PDU.
1. Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit.
2. Plug the other end of the power cord into the power receptacle.
The 1152A1 PDU powers up, and the internal fans begin operating.
The 1152A1 PDU then runs through its Power On Self Test (POST), which takes less than
10 seconds. During the test, all the ports on the unit are disabled and the LEDs light up. For
more information on the test, refer to the user’s guide that comes with the unit.
Connecting the 1152A1 PDU cables
All of the ports on the front of the 1152A1 PDU are configured as data route-through ports for all
data wires (pins 1, 2, 3 and 6).
Use a standard CAT5, CAT6 or CAT6e straight-through Ethernet cable (not supplied), including
all 8 wires (4 pairs) as shown in
Connecting cables to telephones and other end devices
on
page 394.
Figure 22: Connecting telephones and other end devices to the 1152A1 PDU
AC
Console
1
2
3
4
5
6
13
14
15
16
17
18
19
20
21
22
23
24
7
8
9
10
11
12
1152A1 Power
Distribution Unit
Data &
Power
Data
48Vdc
End Device
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45 IN
RJ-45 OUT
Ethernet
Switch/Hub
RJ
-4
5
RJ
-4
5
data
data
data
DC +
data
DC -
data
data
data
data
spare
spare
spare
spare
Da
ta
In
Da
ta
&
P
ow
e
r O
u
t
DC +
DC -
1152A1 Power Distribution Unit