Connecting the grounding cable
Note:
Note:
The grounding cable must meet the following specifications:
- Be 10 AWG
- Able to handle up to 8 Amps amperage
- Have a ring-type, vinyl-insulated TV14-6R lug or equivalent to accommodate the 10
AWG cable.
1. Connect the grounding cable to an earth ground.
2. Attach the lug on the cable to the chassis grounding point, with the screw (see
,
).
Figure 4: Grounding and power connections to the J4350 chassis
Figure 5: Grounding and power connections to the J6350 chassis