Installation
14 Avaya IR R1.2 Installation
software. The NMS package (called AVnms) will not install properly if the cards
are not in the PCI slots.
See the following documents for specific information about how to install the NMS telephony
cards required for the Avaya IR system:
Sun Blade 150 Service
Manual
or
Sun Fire
280R Server Owner's
Manual
These documents provide information about the platform and the PCI
card slots for the telephony cards. These documents are available in
Avaya IR System Help
(under "Print documents") or from the Sun Web
site (http://www.sun.com).
AG4000 Installation and
Developer's Manual
This document describes specific procedures for installing the AG4000
cards in the PCI slots and connecting the cards to the telephone
network. This document is available in
Avaya IR System Help
(under
"Print documents") or from the NMS Web site
(http://www.nmscommunications.com).
PCI slotting rules
Each platform provides two PCI slots for use with the NMS telephony cards.You must install
the telephony cards according the specific rules for each Avaya IR platform.
Sun Blade 150 slotting rules
The Sun Blade 150 has three PCI slots (PCI-1, PCI-2, and PCI-3). The following rules govern
the number and placement of the telephony cards for systems using this platform:
•
System must have a minimum of 0 and a maximum of 2 telephony cards (T1 or E1).
•
Install only the NMS AG-4000 dual telephony cards with two digital interfaces.
•
Unused digital interfaces must be terminated with loop around plug (provided by NMS).
•
If one telephony card is used, install in PCI-1 slot. If two cards are used, install in PCI-1
and PCI-2 slots.
•
The third PCI slot (PCI-3) is always unused.
Sun Fire 280R slotting rules
The Sun Fire 280R has four PCI slots (PCI-1, PCI-2, PCI-3, and PCI-4). The following rules
govern the number and placement of the telephony cards for systems using this platform:
•
System must have a minimum of 0 and a maximum of 2 NMS telephony cards (T1 or E1).