Diagnostics
The following table contains a summary of the diagnostics available for the D100 base station.
If any of the following diagnostic checks fail to complete, reboot the base station. If problems
persist, the hardware might need replacing.
The administrator performs the diagnostic checks on the handset through the
Diagnostics
menu, which only the administrator can enter.
Item
Purpose/Behaviour
LED Check
To check the operation of the LED.
The Power LED flashes for three seconds, followed by the Status LED for
the same duration. The message
Checking LED
also flashes on the
display during the check.
If the check fails, the LED does not display the correct status.
KEY Check
To check the operation of the Registration Key on the base station.
The display reads
Hold Reg. Key
. When you hold the
Registration
key,
the base station detects the registration.
If the base station fails detection, the
Registration
key does not perform
registration.
RAM Check
To check the status of the RAM.
The message
Checking RAM
flashes on the display.
If the check fails, the base station might behave unexpectedly.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
PHY Check
To check the status of the PHY register.
If the PHY check is successful, press the
Details
soft key to view more
information on
Link
,
Duplex
, and
Speed
.
If the check fails, the base station cannot connect to IP Office.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
Flash Check
To check the status of the flash memory.
The message
Checking Flash
flashes on the display.
If the check fails, the base station might behave unexpectedly.
*Can be run in maintenance mode using the Base Station Web
Management Interface*
RF Check
To check the status of the RF register.
If the check fails, the base station cannot transmit data to the handset
correctly.
*Can only be invoked using the Base Station Web Management Interface*
Procedure
1. From the
Administrator Setting
menu, use the
Next
and
Prev
soft keys to navigate
to
Diagnostics
and press the
Select
soft key.
2. Navigate the diagnostics submenu and select the desired item using the
Select
soft
key.
Administration and maintenance
62 D100 SIP Wireless Terminal Installation and Administration Guide
December 2012