PARTNER® Version, Installation and Reference Manual
Page 83
- Issue 1a (30 January 2010)
IP Office Essential Edition
System Component Details: Physical Ports
2
Not used.
1
3
Not used.
2
4
Signal 1.
3
5
Signal 2.
4
6
Not used.
5
7
Not used.
6
8
Not used.
–
·
Part Number: 700047871.
4.9.10 PRI Port
These ports are used for connection to PRI trunk services including E1, T1 and E1-R2.
PRI Trunk Cable
This cable is used to connect from trunk ports to the line providers network termination equipment. If that equipment
does not use RJ45 sockets, the cable may need to be stripped and rewired or an alternative cable used. The appropriate
signal pin-outs and wire colors are detailed below.
IP Office
Wire
Network Termination
RJ45
PRI
PIN
RJ45
1
Rx-A
White/Orange
1
2
Rx-B
Orange/White
2
3
–
White/Green
3
4
Tx-A
Blue/White
4
5
Tx-B
White/Blue
5
6
–
Green/White
6
7
–
White/Brown
7
8
–
Brown/White
8
·
Supply: PRI trunks cards are not supplied with these cables.
·
Cable Color: Red.
·
Part number: 700213440.
·
Standard Length: 3m/9'10".
4.9.11 RS232 DTE Port
This port is found on the rear of the control unit and external expansion modules. The DTE ports on external expansion
modules are not used.
The RS232 DTE port on the control unit can be used for system maintenance and connection of serial terminal adaptors.
An asynchronous terminal program such as HyperTerminal is also required to manage the serial data exchange.
Configure this for operation via a PC serial port, as follows:
Bits per second 38,400
Parity None
Flow Control None
Data bits 8
Stop Bits 1
Settings | Emulation TTY