Deploying Avaya IP Office™ Platform IP500 V2
Page 37
15-601042 Issue 30j (18 May 2015)
IP Office™ Platform 9.1
Comments on this document? infodev@avaya.com
System Overview: Power Supplies and Cables
1.10 Wall and Rack Mounting
All the IP Office control units are designed to be free-standing. On systems with external expansion modules, the control
unit and modules are intended to be stacked.
Using additional option mounting kits, some systems can be wall or rack mounted.
Control/Expansion Unit
Wall Mount
Rack
Mount
IP500 Control Unit
IP500 V2 Control Unit
IP500 External Expansion Modules
Wall Mounting
IP500 V2 control units and IP500 external expansion modules can be wall or rack mounted. To do this, a wall mounting
kit is required in addition to suitable wall fixings.
In addition to the existing
environmental requirements
for an IP Office system, the following additional requirements
apply when wall mounting a unit:
·
The wall surface must be vertical, flat and vibration free. Attachment to temporary walls is not supported.
·
Only the screws provided with the mounting kit should used to attach the brackets to the control unit.
The following wall and rack mounting kit is currently available:
·
IPO IP500 RACK MNTG KIT V3 (SAP Code 700503160)
These kits can be used for wall and rack mounting of an IP500 V2 control unit and IP500 external expansion
modules. The kits incorporates cable routing at the front and rear of the unit. For wall mounted control units it
allows orientation of the control unit base card slots to the left or to the right.
Rack Mounting
All IP Office control units and external expansion modules can be rack mounted into standard 19" rack systems. Each unit
requires a 2U slot space within the rack. The IPO IP500 RACK MNTG KIT V3 is used for rack mounting of units.
Where IP Office systems are being rack mounted, the effect of conditions within the rack cabinet must be considered. For
example the rack temperature may be above the room temperature and airflow within the rack will be restricted. The
environmental requirements
for the individual IP Office units are still applicable inside the rack cabinet.
Barrier Box Rack Mounting Kit
·
Barrier Box Rack Mounting Kit (SAP 700293905)
Barrier boxes must be used for
out-of-building analog phone
extensions
. This bracket allows up to 8 IP Office barrier boxes to
be rack mounted and simplifies the number of connections to the
protective ground point in the rack. This kit must be used when more
than 3 barrier boxes are in use and supports a maximum of 16
barrier boxes for a single external expansion module.
52
52
36