Installation Requirements: Space Requirements
2.2.3 Wall Mounting
IP500 V2 control units and IP500 external expansion modules can be wall or rack mounted. To do this, a wall mounting
kit is required in addition to suitable wall fixings.
In addition to the existing
environmental requirements
for an IP Office system, the following additional requirements
apply when wall mounting a unit:
·
The wall surface must be vertical, flat and vibration free. Attachment to temporary walls is not supported.
·
Only the screws provided with the mounting kit should used to attach the brackets to the control unit.
The following wall and rack mounting kit is currently available:
·
IPO IP500 RACK MNTG KIT V3 (SAP Code 700503160)
These kits can be used for wall and rack mounting of an IP500 V2 control unit and IP500 external expansion
modules. The kits incorporates cable routing at the front and rear of the unit. For wall mounted control units it
allows orientation of the control unit base card slots to the left or to the right.