Installing IP500/IP500 V2
Page 235
15-601042 Issue 28c (19 August 2013)
IP Office 9.0
System Components: IP500 Trunk Daughter Cards
10.4.1 Analog Trunk Card
These cards can be added to an IP500 base card to provide that card with support for 4 loop-start analog trunks. The
newer IP500 Analog Trunk Card V2 version is supported by IP500 V2 systems running IP Office Release 8.1 Feature Pack
1 or higher only.
This card can be fitted to any IP500 base card except the IP500 Legacy Carrier card and IP500 4-Port Expansion card.
·
IP500 Control Unit - V1:
, V2:
·
IP500 V2 Control Unit - V1:
, V2:
·
Ports/Channels
4 Loop-start analog trunk ports. Connections via the host IP500 base card.
·
DTMF, ICLID and busy tone detection.
·
Over-voltage/lightning protection (may still require
additional protection
equipment
).
·
DTMF and LD (loop disconnect) dialing.
·
Echo cancellation.
·
Echo Cancellation
The card supported echo cancellation that varies depending on the card
type.
·
V1: Echo cancellation manually selectable to either 8, 16, 32, 64 or
128 milliseconds or Off. The default is 16 milliseconds.
·
V2: Echo cancellation manually selectable to either On or Off. The
default is On. The IP500 Analog Trunk Card V2 also supports echo
reduction which is set to On by default.
·
Service Status/Line Status Indication
·
V1: Detection of individual line status for idle lines is not supported.
Therefore, the card LEDs and System Status Application simply indicate
that the card is installed and when the line is in use.
·
V2: Automatic detection of line status for idle lines is supported. The
card LEDs and System Status Application indicate that the individual
line is connected and idle or is in use.
·
Impedance Matching
·
V1: For this card only manual impedance matching is useable and only
in selected locales.
·
V2: This card supports automatic impedance matching at system
startup and this mode is enabled by default. Manual or no impedance
matching can be used if required. Impedance matching is supported in
all locales.
·
Power Failure Port
Regardless of the IP500 card hosting it, during power failure pins 4 and 5 of
port 12 are connected to pins 7 and 8. In addition, when fitted to an IP500
Analog Phone 8 base card, during power failure extension port 8 is
connected to the analog trunk port 12.
·
License: No license required.
·
Maximum per Control Unit: 4.
·
IP Office Software Level:
This depends on the version of the card as follow:
·
V1: 4.0+. IP500 and IP500 V2.
New build PCS10 and higher cards are only supported in systems
running IP Office Release 6.1(20), 7.0(12) or 8.0 and higher. Refer to
IP Office Technical Tip 237.
·
V2: 8.1 Feature Pack 1+, IP500 V2 only.
45
Summary of Contents for IP500
Page 1: ...15 601042 Issue 28c 19 August 2013 Installing IP500 IP500 V2 IP Office 9 0 ...
Page 10: ......
Page 12: ......
Page 58: ......
Page 120: ......
Page 132: ...Installing IP500 IP500 V2 Page 132 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 138: ...Installing IP500 IP500 V2 Page 138 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...
Page 422: ......
Page 434: ......
Page 440: ......
Page 441: ...Installing IP500 IP500 V2 Page 441 15 601042 Issue 28c 19 August 2013 IP Office 9 0 ...