Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit Packs
222
SI Installation and Upgrades
June 2004
Duplicated DS1 Converter Complex Administration for
E1 TN1654
Circuit Packs
Return to Task List
Figure 46, Fiber Link Administration form for B-PNC DS1 Converter (DS1CONV) Attributes,
on page
222 allows you to admininster the DS1 converter.
The following unique fields display when administering a E1 TN1654 DS1 Converter.
•
Bit Rate
—
Displays when the DS1 Converter circuit pack is TN1654. Enter either 1.544 for
domestic (USA) T1 operation or 2.048 for international E1 operation.
NOTE:
Since one bit rate applies for all facilities within the same DS1 Converter complex, Bit
Rate displays only under Facility A. To activate the desired Bit Rate, the toggle switch on
the circuit pack must be set and it must correspond to the Bit Rate.
•
Idle Code MSB(1) ... LSB(8)
—
Displays when the DS1 Converter circuit pack is TN1654.
Enter 8 digits, each digit must be 0 or 1. The second digit must be 1. Default is 11101000. You can
administer this field on a per circuit pack basis.
•
CRC
—
Displays when the DS1 Converter circuit pack is TN1654 and the Bit Rate is 2.048
Mbps. Enter yes to receive a “yellow 2” alarm for E1 operation. Default is no. You can administer
this field on a per circuit pack basis.
•
Line Termination
—
A display-only field for DS1 Converter circuit packs that are TN1654 and
have a Bit Rate of 2.048 Mbps. It identifies facility connections as CEPT 75 ohm coaxial or 120
ohm CEPT twisted pair.
Figure 46: Fiber Link Administration form for B-PNC DS1 Converter (DS1CONV)
Attributes
Return to Task List
add fiber-link next
Page 3 of 3
FIBER LINK ADMINISTRATION
B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01C01
DS1CONV Board Location: 02C01
DS1CONV Board Type: TN1654
DS1CONV Board Type: TN1654
DS1 CONVERTER FACILITIES
A
B
C
D
Facility Installed?
yes
yes
yes
no
Bit Rate:
2.048
Facility Startup Idle Code:
11101000
Line Coding:
hdb3
hdb3
hdb3
hdb3
CRC?
yes
Line Termination:
Facility A Circuit ID: 0AABB01
Facility B Circuit ID: 0CCDD02
Facility C Circuit ID: 0EEFF03