Install and Connect SCC1 (Single-Carrier Cabinets)
Connect Time Division Multiplexing Bus Cables
388
SI Installation and Upgrades
June 2004
High or Critical Reliability PPN - Three Cabinet Stack
Return to Task List
1
Remove the Time Division Multiplexing (TDM) Bus Terminator from Slot 18 of Control Cabinet
A (Processor Port Network (PPN)) and move it to Slot 17 on the top port cabinet. See
Figure 122,
Connections for High or Critical Reliability Systems,
on page 388.
2
Connect the supplied TDM Bus Cables (WP-91716 L3) as shown.
Figure 122: Connections for High or Critical Reliability Systems
Return to Task List
Figure notes
1
AHF110 TDM Bus Terminator (Slot 17)
2
TDM/Local Area Network (TDM/LAN)
Pinfield (Slot 00)
3
TDM bus Cable (WP-91716 L3)
4
Port Cabinet
5
Control Cabinet A Position
6
AHF110 TDM Bus Terminator (Slot 03)
7
Slot 18
8
Inter-Cabinet Cables (ICC) B and C
(H600-259-G1)
9
Duplicated Control Cabinet B Position
3
3
3
7
4
4
9
5
1
2
2
2
8
8
6
tdm_cab4 CJL 053096