Upgrade Firmware on Programmable Circuit Packs
Self and C-LAN-distributed download Procedure
724
SI Installation and Upgrades
June 2004
If you are performing a C-LAN-distributed download, enter a C-LAN location as the source and 1
to 50 target locations, where the target boards are all of the same type. The following screen
provides an example of a C-LAN-distributed download to 2 UDS1 circuit packs.
3
Press Enter to submit the schedule.
If you set the
Schedule Download
field to n, the download starts as soon as you submit the
schedule.
NOTE:
If you are scheduling firmware downloads for a circuit pack that is designated as
primary/secondary sync (timing) source (for example, TN464GP), this procedure
automatically redesignates a local timing source during the download. After the download
is complete and the circuit pack is returned to service, the procedure designates the
original circuit pack as the timing source.
NOTE:
The target circuit packs are automatically removed from service while the firmware is
downloaded to them and automatically returned to service after the download is
completed. While a circuit pack is removed from service, any active calls through that
circuit pack are dropped.
NOTE:
An error message asking you to use the command,
test firmware download
, means that
there was a problem with a previous firmware download. Run the test before proceeding.
Go to
Testing firmware download
on page 727.
CAUTION:
Unless the
Remove Image File After Successful Download
field is set to
y, the
ftplogin
and
ftppassword
remain on the TN799DP or TN799C (C-LAN) and
TN2501AP (VAL) circuit packs either until they are reset or until you type the
disable
filesystem board
UUCSS
command.
change firmware download Page 1 of 1
FIRMWARE DOWNLOAD
Source Board Location:
01A04
Firmware Image File Name:
usd1v22r1
Target Board Code:
TN464
Suffix:
GP
Firmware Vintage:
Schedule Download?
y
Remove Image File After Successful Download?
y
Start Date/Time:
10/08/2002 22:00
Stop Date/Time:
10/08/2002 22:30
Target Target Target Target Target
Location Location Location Location Location
1.
01B04
11. _____ 21. _____ 31. _____ 41 _____
2.
01B05
12. _____ 22. _____ 32. _____ 42 _____
3. _____ 13. _____ 23. _____ 33. _____ 43. _____
4. _____ 14. _____ 24. _____ 34. _____ 44. _____
5. _____ 15. _____ 25. _____ 35. _____ 45. _____
6. _____ 16. _____ 26. _____ 36. _____ 46. _____
7. _____ 17. _____ 27. _____ 37. _____ 47. _____
8. _____ 18. _____ 28. _____ 38. _____ 48. _____
9. _____ 19. _____ 29. _____ 39. _____ 49. _____
10. _____ 20. _____ 30. _____ 40. _____ 50. _____
Enter 5 character board number; cabinet(1-30):carrier(A-E):slot(0-20)