P116T Stackable Switch Installation Guide 

1

 

 

Preface 

Important information  

SAFETY PRECAUTIONS 

CAUTION – TO REDUCE THE RISK OF ELECTRIC  SHOCK AND FIRE 

1.  All servicing should be undertaken ONLY by qualified personnel. The parts 

inside the unit CANNOT be serviced or repaired by the end user. Please call 
your service representative for assistance. 

2.  Do NOT plug in, turn on or attempt to operate a damaged unit. 
3.  Ensure that the chassis ventilation slots in the unit are NOT BLOCKED. 
4.  Replace a “blown” fuse only with the same type and rating as is marked on the 

safety label adjacent to the power inlet housing the fuse. 

5.  DO NOT operate the unit in a location where the maximum ambient 

temperature exceeds 40ºC. 

6.  Be sure to  unplug the power supply cord from the wall socket BEFORE 

attempting to remove and/or check the main power fuse. 

PRECAUTIONS DE SECURITÉ 

AVERTISSEMENT – POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE ET D’INCENDIE 

1.  Tout entretien doit être fait UNIQUEMENT par un personnel de service 

qualifié. Aucun élément ne peut être réparé par un particulier. 

2.  NE PAS brancher, allumer ou essayer de faire fonctionner une unité sur 

laquelle un doute existe quant à son bon fonctionnement. 

3.  S’assurer que les ouvertures d’aération du châssis dans l’appareil NE SONT 

PAS OBSTRUEES.. 

4.  Remplacer un fusible défaillant UNIQUEMENT par un modèle du même type 

suivant les recommandations indiquées sur l’étiquette de securité posée dans 
le logement du fusible. 

5.  NE PAS faire fonctionner l’appareil dans un endroit où la temperature dépasse 

les 40ºC. 

6.  S’assurer de débrancher l’alimentation électrique AVANT toute manipulation 

sur le fusible principal. 

SICHERHEITSVORKEHRUNG 

ACHTUNG – ZUR VERHINDERUNG DES RISIKOS VON ELEKTRISCHEM SCHLAG UND FEUER 

1.  Die Geräte enthalten keine Bauteile, die außerhalb des Avaya Servicezentrums 

gewartet oder repariert werden können. Die Wartung darf NUR von 
qualifiziertem, technischem Personal durchgeführt werden. 

2.  NIEMALS ein beschädigtes Gerät einschalten, oder versuchen es zu bedienen. 

Summary of Contents for P116T

Page 1: ...Avaya Installation Guide Avaya P116T STACKABLE SWITCH ...

Page 2: ......

Page 3: ...TRIQUE ET D INCENDIE 1 Tout entretien doit être fait UNIQUEMENT par un personnel de service qualifié Aucun élément ne peut être réparé par un particulier 2 NE PAS brancher allumer ou essayer de faire fonctionner une unité sur laquelle un doute existe quant à son bon fonctionnement 3 S assurer que les ouvertures d aération du châssis dans l appareil NE SONT PAS OBSTRUEES 4 Remplacer un fusible défa...

Page 4: ...en Sicherung NUR mit der gleichen Sorte und Belastbarkeit wie sie auf der Sicherheitsaufschrift markiert ist Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet 5 Bedienen Sie das Gerät NICHT an einer Stelle an der die Umgebungstemperatur 40ºC übersteigt 6 Ziehen Sie das Netzkabel raus BEVOR Sie versuchen die Hauptsicherung zu kontrollieren oder auszutausc...

Page 5: ...he switches The units are physically linked using the P110 Exoplane which makes up a multi gigabit non blocking backplane Any combination of two three or four P110 switches can be stacked and up 32 000 MAC addresses per stack are supported Only three P116T hubs can be connected on a stack and a fourth switch can be connected to the stack only if it is a different P110 model All ports can run at fu...

Page 6: ...Chapter 1 Description 4 P116T Stackable Switch Installation Guide ...

Page 7: ...1 16 Selects whether the port will operate at 10 Mbps or 100 Mbps USE SW Use Switches Selects whether the 10 100 mode will be controlled from the management station or by the DIP switches When set to ON 10 100 Mbps switch settings are determined by the DIP switches only Settings can be monitored but not changed by the management station When set to OFF the DIP switch settings are ignored and the 1...

Page 8: ...Selection of port speed 10 Mbps 100 Mbps Default second switch from the right Not used USE SW Use Switch Selection of operational mode control by management station or DIP switches Ignore management settings Use switches Default Use management settings Ignore switches Once you have set the switches you may proceed with the physical installation of the hub ...

Page 9: ...re version 8 4 or higher is required See the Release Notes for the required version You should make sure the P110 NMA has the latest agent software To check what software version you have see the agent configuration window in CajunView or MSNM or see the setup main menu of the P110 NMA 2 Before adding a switch to the P110 stack turn off the main power to the stack by individually switching off eac...

Page 10: ...ghbor through two P110 Exoplane cables and to its lower neighbor through another two Exoplane cables Make sure that the P110 Exoplane cables are correctly seated by gently exerting pressure on the back of the connector Cabling Requirements For correct operation the P110 Exoplane must be fully connected with all units powered up In case units are stacked the P110 NMA must be installed and connected...

Page 11: ...om of the stack as shown in Figure 2 7 Turn on the mains power to the stack by individually switching on each switch 8 Connect the fiber optic cables to the front panel ports If the P110 NMA in the stack contains the correct software version as specified in the P116T Stackable Switch Release Note or higher the stack is now fully operational When a new version of the P110 NMA software becomes avail...

Page 12: ...tches into the rack so that the switches in a logical stack lie directly on top of each other Ensure that the P110 screw holes are aligned with the rack hole positions exactly as shown in Figure 3 Stacking them in this way will allow the switches to be easily connected using the Exoplane cables 3 Secure the switch in the rack using the screws Use one screw on each side Do not overtighten the screw...

Page 13: ... the 16 Port LEDs the top two rows of LEDs The seven Function LEDs above the Select buttons show which function is currently displayed by the Port LEDs The Port LEDs can display either Link Collision Transmit Receive Full Duplex Flow Control or 100 M status If for example the Link LNK LED is lit then LEDs 1 to 16 will display the Link status of every port Press the left or right button to toggle t...

Page 14: ...lowing functions Link Collision Transmit Receive Full Duplex Flow Control or 100 M states depending on what has been selected using the Select buttons Function LED Port LED LNK Link status OFF ON Blink once Port Disabled Port is enabled and link is OK Link Test Fail COL Collision OFF ON No Collision Collision occurred on line Tx Transmit to line OFF ON No activity Data transmitted Rx Receive from ...

Page 15: ...Chapter 2 Installation P116T Stackable Switch Installation Guide 13 ...

Page 16: ...hts reserved All trademarks identified by the or TM are registered trademarks or trademarks respectively of Avaya Inc All other trademarks are the property of their respective owners Document number 130007 Rev 0 November 2003 ...

Reviews: