Caution!
You need two people for the next step.
5. Mount the server in the cabinet:
a. Fully extend the slide out the front of the cabinet. See Item 6 in
Attaching a rack-mount rail
assembly on an S3210R server
.
b. Have one person hold up the front of the server. Have a second person help support the server,
and guide the server onto the slide.
6. Repeat Steps 1 through 5 for each server that must be installed.
7. When all servers are mounted, continue with
Connecting the power cables
.
Installing the server in a stackable desktop configuration
If the server is to be installed in a stackable desktop configuration with the UPS and an EBM, you must install
four rubber spacers on the bottom on the server.
Caution!
If you are installing more than one Message Networking system, do not stack more than two on top of
each other. Create multiple stacks if needed. If you have a UPS
and
an EBM, stack only one server on top of
them. The EBM is supported for the S3400-H only.
To install the servers in a stackable desktop configuration:
1. Gather the rubber spacers shipped with each server.
2. Attach the rubber spacers to the bottom of the server, one at each corner. See
Rubber spacers for
stackable configuration
.
3. Position the UPS or EBM (always the bottom unit if present) in an appropriate location. See
Site
requirements
for details.
4. Place the server on top of the UPS.
5. Continue with
Connecting the power cables
.
Top of page