ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 May 2002
8-279
555-233-143
19
Multiplexer
Section Remote
Defect Indicator:
MS_RDI
The far end is detecting a major problem with the signal that this
board is transmitting.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-TRK board) is the same as
the ATM-TRK circuit pack’s cable interface
2. Run test board UUCSS command.
3. If Test #1259 fails with Error Code 19, connect a fiber
back-to-back in a looped mode (one strand of fiber connecting
the transmit transceiver to the receive transceiver of the board)
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack; if
the error persists, escalate the problem.
20
Loss of pointer:
LOP
ATM framer chip is unable to access the payload part of the signal.
1. Reset the board (reset board UUCSS).
2. If the error persists replace the board.
21
Path Signal Error
(PSL)
(STM1/SONET)
The incoming signal payload is not set up for transmission of ATM
data.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-TRK board) is the same as
the ATM-TRK circuit pack’s cable interface.
22
High-level Path
Alarm Indication
Signal:
HP_AIS
The payload is invalid.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-TRK board) is the same as
the ATM-TRK circuit pack’s cable interface.
2. Run test board UUCSS.
3. If Test #1259 fails with Error Code 22, connect a fiber
back-to-back in a looped mode (one strand of fiber connecting
the transmit transceiver to the receive transceiver of the board)
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack.
Table 8-120.
Error type 1281 Aux Data and repair procedures —
Continued
Aux
Data
Alarm
Description
Repair procedure
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...