Maintenance-Object Repair Procedures
555-233-143
8-284
Issue 1 May 2002
1. Run test board UUCSS long.
s. Error Type 3841: the ATM-TRK circuit pack received an unrecognized
message from the switch and responded with an inconsistent down-link
error message.
1. Do nothing. This error does not affect service.
t. Error Type 3842: LANHO Receive FIFO Overflow error; the packet bus is
delivering data to the ATM-TRK circuit pack faster than the circuit pack can
distribute it to the endpoint.
1. Do nothing. The circuit pack can recover by itself.
u. Error Type 3843: The firmware on the circuit pack is reporting a resource
that is to low. This error does not affect the service and no action is
required.
v. Error Type 3999: circuit pack sent a large number of control channel
messages to the switch within a short period of time.
If
Then
Test #1259 fails with Error
Code XXYY and XX is an
AUX value in the preceding
table
Replace the ATM-TRK circuit pack.
The system does not
recognize the circuit pack
Replace the ATM-TRK circuit pack.
If
Then
Error Type 1538 is also
present
Circuit pack is taken out of service.
Error Type 1538 is absent
Circuit pack is not taken out of service,
but has generated 50% of the messages
necessary to be considered hyperactive.
■
This can be normal during heavy
traffic.
■
If the error is logged during light
traffic, it can indicate a problem with
the circuit pack or the equipment
attached to it.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...